Technical remarks
Gas Flow Interruption
On a gas-heated drier, the electronic ignition will only try to ignite five times in
a time span of 5 seconds. If this does not work, and the flame detector does not
detect a flame (e.g. in the event of a gas flow interruption), the ignition relay is
triggered. When the drying cycle is
restarted
, the reset button shall be pressed for
three seconds in order to generate a new ignition.
Electronic temperature
protection
When a temperature of
5°C or less, or of 120°C or more
has been detected, the
electronic temperature protection will be activated.
During operation :
Temperature higher than
120°C
:
Every action is interrupted.
“tMp”
is blinking on the display.
Temperature lower than
5°C
:
The heating is interrupted but the cycle will be completed.
“tMP”
is blinking on
the display at the end of the cycle.
During non-operation :
“tMP”
is blinking on the display and the cycle can’t be started anymore.
Because of these protections, the dryer can’t be used at a temperature
of less than 5°C.
Underpressure switch
In case the drum no longer rotates due to failure (for instance breakdown of a V-
belt),
" rot "
will appear blinking on the display if the machine is equipped with
a rotation sensor (option) and the cycle continues without activating the heating.
The rotation sensor is fixed at the back of the dryer near the drum axle.
The underpressure switch is a protection which interrupts the heating, in
case there is insufficient air supply. This can be the result of an inadequate
exhaust (see installation), of a dirty filter (see maintenance).
In case of a malfunction,
" VEn "
appears blinking on the display and
the cycle continues without activating the heating.
Rotation sensor
If the machine is equipped
with a rotation sensor
, the bridge (A) on the
printboard needs to be
cut through
. If not, the same error message will
be shown on display.
Summary of Contents for DTI10
Page 2: ......
Page 3: ......
Page 4: ......
Page 12: ...9 4 ...
Page 14: ...11 4 ...
Page 16: ...13 4 ...
Page 18: ...15 ...
Page 20: ...17 ...
Page 22: ...19 4 ...
Page 24: ...21 4 ...
Page 26: ...23 4 ...
Page 28: ...25 ...
Page 30: ...27 ...
Page 34: ...31 ...
Page 45: ...1 DTI10 DTI14 CD220 350 ...
Page 47: ...1 DTI10 DTI14 CD 220 350 ...
Page 49: ...2 DTI10 DTI14 CD 220 350 ...
Page 51: ...3 DTI10 DTI14 CD 220 350 ...
Page 53: ...4 DTI10 DTI14 CD 220 350 ...
Page 55: ...5 DTI10 DTI14 CD 220 350 ...
Page 57: ...6 DTI10 DTI14 CD 220 350 ...
Page 59: ...7 DTI10 DTI14 CD 220 350 ...
Page 61: ...8 DTI10 DTI14 CD 220 350 ...
Page 63: ...9 DTI10 DTI14 CD 220 350 ...
Page 65: ...10 DTI10 DTI14 CD 220 350 ...
Page 67: ...11 DTI10 DTI14 CD 220 350 ...
Page 69: ...12 DTI10 DTI14 CD 220 350 ...
Page 71: ...13 DTI10 DTI14 CD 220 350 ...
Page 73: ...14 DTI10 DTI14 CD 220 350 ...
Page 75: ...15 DTI10 DTI14 CD 220 350 ...
Page 77: ...15 DTI10 DTI14 CD 220 350 ...
Page 79: ...16 DTI10 DTI14 CD 220 350 ...
Page 81: ...17 DTI10 DTI14 CD 220 350 ...
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......