background image

USER’S MANUAL

QUESTIONS?

If you have questions, or if there
are missing parts, we will guar-
antee complete satisfaction
through direct assistance from
our factory.

TO AVOID DELAYS, PLEASE
CALL DIRECT TO OUR TOLL-
FREE CUSTOMER HOT LINE.
The trained technicians on our
customer hot line will provide
immediate assistance, free of
charge to you.  

CUSTOMER HOT LINE:  

1-877-897-7493

Mon.–Fri., 8 a.m.–5 p.m. CST

CAUTION

Read all precautions and instruc-
tions in this manual before using
this equipment. Save this manual
for future reference.

Visit our website at

www.weslo.com

new products, prizes,

fitness tips, and much more!

Access Panel

Model No. WLSB61520

WLSG61520

Serial No. 

The serial number is found on a plastic
sign inside the spa behind the access
panel. Write the serial number in the
space above for reference. 

Summary of Contents for Daybreak 615

Page 1: ...iate assistance free of charge to you CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manua...

Page 2: ...Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Page 5: ...ll users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on th...

Page 6: ...d to feel your best For your benefit read this manual carefully before using the DAYBREAK 615 If you have questions after reading the manual call our Customer Service Department toll free at 1 877 897...

Page 7: ...provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If yo...

Page 8: ...etal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two pages Rem...

Page 9: ...ovided on the inside of the electronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that...

Page 10: ...ning proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING...

Page 11: ...hem F The two fixed jets are always on G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with minimal chemical treatme...

Page 12: ...ter The temperature can be set between 80 F and 104 F The water heats at about 6 F per hour with the cover on Use a medical or other accu rate thermometer to check the temperature of the water Note Th...

Page 13: ...dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with...

Page 14: ...testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 to 5 hours Press the temp up or temp down butt...

Page 15: ...1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest...

Page 16: ...main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See t...

Page 17: ...MPTOM NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTER CLOCKWISE a If no air flows through the hydrotherapy jets when the air control is turned counterclock...

Page 18: ...Drain Plug 28 1 Drain Plug O ring 29 4 Rubber Washer 30 4 Buckle 31 8 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Diverter Plate 34 2 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 8 Nozzle Retain...

Page 19: ...8 13 20 11 7 2 7 5 25 25 25 10 9 9 13 42 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 40 41 46 24 51 47 47 45 18 18 46 46 46 17 17 50 38 38 38 38 15 16 43 8 33 49 48 44 Exploded Drawing Mo...

Page 20: ...the following incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulti...

Reviews: