18
TROUBLESHOOTING AND MAINTENANCE
Make sure all parts are properly tightened each time you use the weight system. Replace any worn parts immedi-
ately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.
TIGHTENING THE CABLES
Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is
slack in the cables before resistance is felt, the cables should be tightened.
Slack can be removed from the Short Cable (23) by
tightening the M8 Nylon Locknut (3) at the end of the
Cable.
Additional slack can be removed by moving the
90mm Pulley (15) to the other hole in the Long “U”-
Bracket (57). Remove the M10 Nylon Locknut (21)
and the M10 x 50mm Bolt (12) from the Pulley
Covers (73), the Pulley, and the “U”-Bracket. Re-
attach the Pulley and the Pulley Covers to the other
hole in the “U”-Bracket with the Bolt and Nylon
Locknut.
Make sure that the Cable and Pulley
move smoothly.
Note: If a cable tends to slip off the pulleys, the
cable may have become twisted. Remove the
cable and re-install it. If a cable needs to be
replaced, see ORDERING REPLACEMENT PARTS
on the back cover of this manual.
57
73
73
15
3
23
12
21
Summary of Contents for Gym 1000
Page 20: ...20 NOTES ...
Page 21: ...21 NOTES ...
Page 26: ... V Pulley 6 Not shown to scale 90mm Pulley 15 Not shown to scale ...