Pro-EC44 2-Loop Graphical Profile Controller & Recorder
Pro-EC44 Product Manual - 59540-2 September 2014
Page 120
Input 2 Signal Over Range Flag
Value
Process Input Over Range Status
Dec
1110
17494 34988
RO
0
Inactive
Hex
0456
4456
88AC
1
Active
(over-range detected)
Input 2 Cold Junction Compensation
Value
CJC Status
Dec
1111
17495 34990
RW
0
Disabled
Hex
0457
4457
88AE
1
Enabled (
default
)
Input 2 Multi-point Scaling Enable
Value
Multi-point Scaling Status
Dec
1129
17513 35026
RW
0
Disabled
Hex
0469
4469
88D2
1
Enabled (
only if the input type is linear
)
Input 2 Scale Point 1
Multi-Point Scaling Point 1
Dec
1130
17514 35028
RW
Percentage of the scaled input where multi-point scaling value 1
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
046A
446A
88D4
Input 2 Display Point 1
Multi-Point Scaling Display Value For Point 1
Dec
1131
17515 35030
RW
Value to display at multi-point scaling point 1
Valid between the scaled input lower & upper limits
Hex
046B
446B
88D6
Input 2 Scale Point 2
Multi-Point Scaling Point 2
Dec
1132
17516 35032
RW
Percentage of the scaled input where multi-point scaling value 2
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
046C
446C
88D8
Input 2 Display Point 2
Multi-Point Scaling Display Value For Point 2
Dec
1133
17517 35034
RW
Value to display at multi-point scaling point 2
Valid between the scaled input lower & upper limits
Hex
046D
446D
88DA
Input 2 Scale Point 3
Multi-Point Scaling Point 3
Dec
1134
17518 35036
RW
Percentage of the scaled input where multi-point scaling value 3
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
046E
446E
88DC
Input 2 Display Point 3
Multi-Point Scaling Display Value For Point 3
Dec
1135
17519 35038
RW
Value to display at multi-point scaling point 3
Valid between the scaled input lower & upper limits
Hex
046F
446F
88DE
Input 2 Scale Point 4
Multi-Point Scaling Point 4
Dec
1136
17520 35040
RW
Percentage of the scaled input where multi-point scaling value 4
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
0470
4470
88E0
Input 2 Display Point 4
Multi-Point Scaling Display Value For Point 4
Dec
1137
17521 35042
RW
Value to display at multi-point scaling point 4
Valid between the scaled input lower & upper limits
Hex
0471
4471
88E2
Input 2 Scale Point 5
Multi-Point Scaling Point 5
Dec
1138
17522 35044
RW
Percentage of the scaled input where multi-point scaling value 5
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
0472
4472
88E4
Input 2 Display Point 5
Multi-Point Scaling Display Value For Point 5
Dec
1139
17523 35046
RW
Value to display at multi-point scaling point 5
Valid between the scaled input lower & upper limits
Hex
0473
4473
88E6
Input 2 Scale Point 6
Multi-Point Scaling Point 6
Dec
1140
17524 35048
RW
Percentage of the scaled input where multi-point scaling value 6
is applied.
0.1 to 100.0% *set to 100% ends scaling sequence at that point.
Hex
0474
4474
88E8
Input 2 Display Point 6
Multi-Point Scaling Display Value For Point 6
Dec
1141
17525 35050
RW
Value to display at multi-point scaling point 6
Valid between the scaled input lower & upper limits
Hex
0475
4475
88EA
Summary of Contents for Pro-EC44
Page 1: ...Pro EC44 2 Loop Graphical Profile Controller Recorder Pro EC44 User Guide 59540 2 ...
Page 2: ......
Page 6: ......