Digital Input Setup
- Sub-menu to setup the Digital Inputs. Press
D
+
R
to return to Input Menu
Digital Input Status
A diagnostic status (
= OFF,
= ON,
Ø
= not available) for digital inputs
A; C1 to C8 and
“Soft “digital inputs S1 to S4. If used for profile selection, it
also shows bit pattern type (binary or BCD) and selected profile number.
Tick Digital Inputs To
Invert
Select digitals input with
to invert their operation (making them appear
OFF when their actual state is ON). Inputs shown as
Ø
are not available.
Profile Selection
Type
Select the bit pattern to be used for profile selection. Binary or BCD (
Binary
Coded Decimal
). Select None if profile selection not is required.
Choose Profile
Selection
For profiler versions, the Multi-Digital Input option can be used to select the
profile to run with a standard binary bit pattern or binary coded decimal
from BCD switches. C1 is the least significant bit (LSB) of the bit pattern.
Profiles are numbered from 0 to 63.
Use the table to choose inputs C1 to C
n
for the number of profiles to select:
C1
C1 to C2 C1 to C3 C1 to C4 C1 to C5 C1 to C6 C1 to C7
Binary
0 to 1
0 to 3
0 to 7
0 to 15
0 to 31
0 to 63
BCD
0 to 1
0 to 3
0 to 7
0 to 9
0 to 19
0 to 39 0 to 63
Any inputs chosen for profile selection are not available for other uses.
– refer to the Digital Inputs on page 75.
Configure Digital
Inputs
Select any available digital input or soft digital input to be configured for
use. The current status of each is shown as Assigned or Unused.
Soft Digital Input
n
Digital Input Logic
Set up a
“Soft” digital input
n
that is the result of the Boolean AND
selections of physical inputs,
globally OR’d with the OR selections.
Press
U
or
D
to select
/ deselect
the options. Inputs shown as
Ø
are
not available
– refer to the Digital Inputs on page 75.
Soft Digital Input
n
Alarm-Event
Further set up of
“Soft” digital input
n
that adds the Boolean OR of Alarms
& Events to the physical digital inputs already selected.
Press
U
or
D
to select
/ deselect
the options. Inputs shown as
Ø
are
not available
– refer to the Digital Inputs on page 75.
Digital Input
n
Function
Select the function to be operated from digital input
n
.
– The possible
functions are:
Loop 1 or 2 Setpoint Select; Loop 1 or 2 Auto/Manual Select; Loop 1 or 2
Control Select; Loop 1 or 2 Pre-Tune Select; Loop 1 or 2 Self-Tune Select
Clear All Latched Outputs; Output
n
Clear Latch; Output
n
Forcing On or
Off; Profile Run/Hold; Profile Hold Segment Release; Profile Abort; Data
Recorder Trigger or Key
n
Mimic (replicating pressing
L
D
U
or
R
).