Pro-EC44 2-Loop Graphical Profile Controller & Recorder
Pro-EC44 Product Manual - 59540-2 September 2014
Page 67
Service & Product Information Mode
This is read only information about the instrument, its modules and enabled features. It has
contact information to tell the user where they can obtain service, sales or technical support
for the product. Normally this is the manufacturer or supplier
s’ details. Using the PC software,
the user can enter their own contact information. There are 7 lines of text - each up to 25
characters in length.
Entry into Service & Product Information Mode
The Service & Product Information Mode is entered from the Main Menu
Hold down
R
and press
U
to enter the Main Menu.
Press
D
or
U
to select the Service & Product Information Mode
Press
R
to enter the Service & Product Information Mode.
Navigating Product Information Mode
Press
R
to move forward or
L
to move backwards through the displayed
information.
Hold down
R
and press
U
to return to the Main Menu
Scrolling “Help Text” is shown at the bottom of the screens to aid navigation.
SERVICE & PRODUCT INFORMATION SCREENS:
Plug-in Module
Information
Lists the type plug-in modules types in Slots 1, 2, 3 or A
– see page 4 for a
full list of field upgradeable plug-in options.
Base Options
Lists factory fitted base options, from: 2nd Universal/Aux input; Output 4 &
5 Relay; Output 6 & 7 Linear mA/V DC.
Optional Features
Lists which other optional features are fitted/enabled, from: Profiler; USB
Port; Data Recorder and 8 Digital Inputs.
Firmware
Information
The type and version of firmware installed in the instrument.
Product Revision
Level
Software and Hardware update status.
Serial Number
The instrument serial number.
Date of Manufacture
The instrument Date of Manufacture (date format is dd/mm/yyyy).
Input 1 Calibration
Status
The base calibration status for each signal type on input 1.
Caution:
Re-calibrate input 1 for mVDC, VDC, mADC, RTD or
Thermocouple CJC if they do not say
“Calibrated” –
see page 72
Input 2 Calibration
Status
The base calibration status for each signal type on optional input 2.
Caution:
Re-calibrate input 2 for mVDC, VDC, mADC, RTD or
Thermocouple CJC if they do not say
“Calibrated” –
see page 72
Calibration Check
Due Date
The date re-calibration is due.
–
only shown if the Calibration Reminder is
enabled in the Input Configuration menu.
For Service Contact
Contact information for service, sales or technical support.
Summary of Contents for Pro-EC44
Page 1: ...Pro EC44 2 Loop Graphical Profile Controller Recorder Pro EC44 User Guide 59540 2 ...
Page 2: ......
Page 6: ......