8
West Mountain Radio
Operating Manual
Specifications
Electronics:
Maximum voltage: 35 VDC
Current:
< 30 mA Normal Mode
< 5mA Sleep Mode
Solid State Switch:
Continuous Current: 30 A
Maximum Current: 40 A
Nominal ON resistance: 5 milliohms
Switching Ranges:
Hi Trip: 15.0 ± 0.1VDC
Low Trip: 11.0 ± 0.1VDC
Auto Re-Start: 13.0 ± 0.1VDC
Switching Time
Hi-Trip: 10 milli-seconds
Constants
Low-Trip: 3.3 Seconds
Mode Select: 5.0 Seconds
Sleep Mode: 60 Min
After the driver is found, start the West Mountain Radio diagnostics utility
program. Find the PWRguard Plus in the list of devices. Right-click on
the PWRguard Plus and select “TEST”. When the terminal window pops
up, press enter in the terminal area and the following menu will appear:
West Mountain Radio P 1.14
1) Reset to factory settings
2) View/Change Settings
3) Monitor mode
4) Force output ON
5) Force output OFF
Function <0>:
If enter “2”, followed by “ENTER, the following options occur:
Press just enter for no change:
High Trip <14.97>:
High Restart (14.81>:
Low Trip <10.97>:
Low Restart <12.96>:
Force unit ON via remote sense(Y,N)<N>?
Force unit OFF via remote sense(Y,N)<Y>?
Auto Restart when voltage is back in range <Y>?
Summary of Contents for PWRguard PLUS