6

0803I2RA

Figure 5.    Close-Up of  Connector Types

Pin 4 (R)

Typical RJ48C Jack

Pin 1 (R1)

Pin 2 (T1)

Pin 5 (T)

1

2

3

4

5

6

7

8

Front

Rear

Amphenol-type 50-pin Male

RCV and XMT Connector

Pin 50

Pin 26

Pin 25

Pin 1

RJ48H

J1 Through J14

J15

Customer Side Connections

CO Side Connections

Pin 50

Pin 26

Pin 25

Pin 1

Customer Side Connections

(Female)

Cable Output Direction

Cable Output Direction

J16

- GROUNDING CAUTION -

Always follow local safety precautions and standard operat-
ing procedures for grounding the equipment when instal-
ling, upgrading, repairing or maintaining equipment. Any
instructions or information contained herein is subordinate
to local codes, operating procedures or practices.

3.5

Grounding

When properly installed, the DSAWM-214 enclosure is a total-
ly grounded system at the installation site. The enclosure
provides points for chassis/frame, circuit ground, cable shield
ground, and a static ground.

 3.5.1

Chassis/Frame Ground Connections

Chassis ground prevents voltage from building up on the sur-
face of the equipment. The enclosure chassis must be
connected to an earth ground at all times in order to properly
ground the enclosure’s metal framework and all module front
panels. A separate ground conductor/wire is recommended for
chassis/frame ground (separate from the circuit ground). One
end of this conductor/wire must be connected to the enclo-
sure’s external ground lug (located near the front of the unit
under the module housing, as shown in Figure 6) and the other
end must be wired directly into the multi-ground neutral of the
building ground. A shorting bar is provided (but not factory-
installed) for optional installation between the CHASSIS
GND and CKT GND terminals on TB1, for applications re-
quiring chassis ground to be connected to circuit ground.

3.5.2

Circuit Ground Connections for Local DC Power

Circuit ground provides a lightning return path and is recom-
mended to be directly and separately connected to earth
ground regardless of the power source or type (local or span).
Circuit ground must be connected to position CKT GND of
TB1 on the 

Telco Termination Module

 for proper operation of

the secondary lightning protection and for proper operation of
the modules plugged into the enclosure. This ground connec-
tion should be made via a separate conductor to the
multi-ground neutral of the building ground.

Position

Label

Function

1

SHIELD

GND

Provides a ground connection point to the
incoming shield wires connected in pin 1 of the
Wirewrap Interface Card.

2

CHASSIS

GND

Provides a ground connection point for the metal
enclosure and DNI front panels.

3

+PWRB/

CKT GND

Provides a connection point for battery return and
connects to pin 17 of all slots. This terminal must
be connected to EARTH to maintain
lightning/overvoltage protection.

4

+PWRA

Provides a connection point for battery return and
connects to pin 17 of all slots. For back-up power
supply.

5

-PWRA

Provides connection point for -48V battery for
back-up power supply.

6

-PWRB

Provides connection point for -48V battery.

Table 1.    TB1 Connections

 3.5.3

Local AC Powering Ground Connections

When local AC is used with the 2555 Power Supply, the GRN/
YEL ground wire on the 2555 may be connected to the
enclosure’s chassis ground screw labelled  POWER SUPPLY
CHASSIS GROUND" located in the center of the enclosure’s
rear back panel. This gives the customer an alternate means of
utilizing the outlet ground through the power supply cord.

Summary of Contents for DSAWM-214ALCI2

Page 1: ...Office CO side connections are made via wirewrap pins mounted on the plug in Telco Termination Mod ule located at the top of the enclosure or via two 50 pin Amphenol type connectors at the top rear of...

Page 2: ...ded that adequate horizontal and vertical space be left between multiple installations to allow for proper cable access and ven tilation The distance from the cable entry point should be consistent wi...

Page 3: ...nnections 3 1 2 2 Local Powering Mode When local power mode is selected TB1 on the Telco Termina tion Module provides screw terminals for 48 V battery PWR position and 48 V return PWR position A separ...

Page 4: ...ck plate from the enclosure by depressing the black metal push buttons located near the bottom on each side of the enclosure 2 Lift and place the back plate on the wall in the desired mounting locatio...

Page 5: ...om mended that spade lugs be used to connect wires to TB1 terminals Figure 7 shows the TB1 DC power and ground con nection locations Power and return ground connections can be made with stripped wire...

Page 6: ...but not factory installed for optional installation between the CHASSIS GND and CKT GND terminals on TB1 for applications re quiring chassis ground to be connected to circuit ground 3 5 2 Circuit Gro...

Page 7: ...de with stripped wire or by spade lug connectors TB1 screw position PWR is the battery return TB1 screw position CKT GND provides cir cuit ground as described in Paragraph 3 5 2 TB1 screw position CHA...

Page 8: ...access to these connections with the wirewrap pin method being the most secure requires a key for access 3 6 1 J1 J14 Connector Wirewrap Pins CO side network facility connections are typically made to...

Page 9: ...le is the following option S1 This 2 position slide switch provides a shield ground from TB1 connected to pins 7 and 8 of the RJ48C jacks J1 through J14 with S1 in the THRU position The shield ground...

Page 10: ...9 14 55 49 T R J16 Voice 800 377 8766 email global_support westell com For additional information about Westell visit the Westell World Wide Web site at http www Westell com 6 2 Part Numbers This equi...

Page 11: ...W O T1 41 4 R BR SGND 1 SGND 1 NC 2 NC 2 R 13 5 O W R 13 5 BR R T 7 6 W O T 7 6 R BR 3 R1 47 POS 3 3 G W 10 R1 47 POS 10 3 S R T1 41 4 W G T1 41 4 R S SGND 1 SGND 1 NC 2 NC 2 R 13 5 G W R 13 5 S R T 7...

Page 12: ...n the defective unit freight prepaid along with a brief problem description to the address we will provide to you when you contact us Voice 630 375 4211 email rgmdept westell com Replacements are ship...

Reviews: