6. Abbreviations and Terms

Abbreviation

Description

AM

Amplitude Modulation

AREMA

American Railway Engineering and Maintenance-of-Way Association

AWG

American Wire Gauge

BPSK

Binary Phase Shift Keying

CAT5e

Category 5 Enhanced Cable

CE

Conformité Européenne

CPU

Central Processing Unit

DC

Direct Current

EMC

Electromagnetic Compatibility

EN

European Standard

ERR

Error

ESD

Electro Static Discharge

ETSI

European Telecommunications Standards Institute

FCC

Federal Communication Commission

FLOSS

Free/Libre Open Source Software

HV

High Voltage

IEC

International Engineering Consortium

IC

Industry Canada

ID

Identification

I/O

Input / Output

IP

Ingress Protection

ISO

International Standardization Organisation

LAN

Local Area Network

LED

Light Emitting Diode

LV

Low Voltage

MIMO

Multiple Input, Multiple Output

MTBF

Mean Time between Failure

MTTR

Mean Time to Repair

OPR

Operation

PM

Pulse Modulated

PoE

Power over Ethernet

QMA

Quick-connect RF Connectors

Ibex-RT-330 Series

31

Summary of Contents for Ibex-RT-330-HV

Page 1: ...www westermo com Ibex RT 330 Series EN 50155 LTE Router...

Page 2: ...Product Description 12 3 1 Product Description 12 3 2 Available models 13 3 3 Hardware Overview 13 3 3 1 Frontside Overview 13 3 3 2 Front Side Label 13 3 3 3 Rear Side Label 14 3 3 4 Interface Ports...

Page 3: ...7 Revision Notes 33 Ibex RT 330 Series 3...

Page 4: ...ww westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description instal...

Page 5: ...ardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides...

Page 6: ...conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that...

Page 7: ...emperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its op...

Page 8: ...ould not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed ove...

Page 9: ...equipment and services Part 52 Specific conditions for Cellular Communication Mobile and portable UE radio and ancillary equipment ECE E Mark Road Vehicles E13 10R 06 15771 valid for LV models only M...

Page 10: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the unit and receiver Connect the product into an outlet on a circuit diff...

Page 11: ...by Westermo declares that this product is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo...

Page 12: ...ators and through SNMP WebGUI The Mobile Communication Gateway router is designed to withstand tough onboard environmental conditions and can be remotely managed using web browser or SNMP management t...

Page 13: ...R X1 X2 6 7 1 3 2 4 8 5 No Description 1 LED indicators 2 SIM card slot 3 Gigabit Ethernet ports X1 and X2 4 Protective earth terminal 5 Power input DC 6 Frontside label 7 Warning symbol for surface t...

Page 14: ...WW AAAAAAAAA Article number RR Region code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week Table 4 Front side label 3 3 3 Rear Side Label Type Ibex RT xxx xx EU...

Page 15: ...oint 5 Power Table 5 Interface ports view 3 4 Connector Information 3 4 1 Power Input Connection Marking Position Direction Description DC 1 DC Positive terminal 2 3 DC Negative terminal 4 Housing Shi...

Page 16: ...kets in slot 1 and or slot 2 with the contacts facing down Let chamfered corners align according markings on the drawer Put the SIM card drawer back into the unit ensuring that it fits into place and...

Page 17: ...4 3 Ethernet Ports The product includes two Ethernet ports X1 and X2 which supports auto negotiated 10 Mbit s 100 Mbit s and 1000 Mbit s operation Automatic MDI MDIX crossover is supported for 10BASE...

Page 18: ...ingress 3 4 4 Antenna Ports The antenna connectors are identified on the product with A1 to A3 QMA industrial standard connector is used A1 and A2 are used for LTE communication Both antennas ports m...

Page 19: ...igure 6 LED indicators LED Description DC Power status OPR Operation status ERR Error status X1 Ethernet status for X1 port X2 Ethernet status for X2 port Table 9 LED indicators NOTE Refer to manageme...

Page 20: ...83 180 111 4 31 35 22 7 22 33 53 5 33 7 7 DC X2 X1 DC ERR X1 X2 OPR 3623 0740 00001089 2012 Power 24VDC 0 6A Ibex RT 330 LV A1 A2 A3 Figure 7 Dimensional drawing 20 Ibex RT 330 Series...

Page 21: ...to ensure proper heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be...

Page 22: ...with a cross section of at least 4 mm2 shall be used The grounding wire is set below the rip lock washer The nut is fixed for good reliable grounding contact The tightening torque of the nut shall be...

Page 23: ...rflow is not blocked and that there is enough spacing around the product Figure 9 Installation with reduced natural convection airflow Figure 10 Installation with natural convection airflow When opera...

Page 24: ...rms Improve installation conditions or RF parameters in case of any temperature alarms 4 6 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement prod...

Page 25: ...mA2 at 110 VDC Startup currenta 2 x nominal current Polarity Reverse polarity protected Redundant power input No Conductor cross section flexible 0 5 mm AWG 20 Cable temperature rating 40 to 70 C Shi...

Page 26: ...bling Shielded cable CAT5e or better is recommended Conductive chassis Yes NOTE The product is to be connected to internal Ethernet networks without exiting a facility and being subjected to TNVs NOTI...

Page 27: ...B39 B41 B66 B12 B29 B30 B5 B14 B30 B66 B29 and B32 are for secondary component carrier only DL 2 CA DL intra band 2CA B2 B2 B3 B3 B4 B4 B7 B7 B25 B25 B38 B38 B39 B39 B40 B40 B41 B41 B66 B66 DL 3 CA D...

Page 28: ...lileo E1B C Supported GNSS constellations GPS GPS Galileo GPS Galileo GLONASS GPS Galileo BeiDou GPS GLONASS GPS BeiDou Galileo Galileo GLONASS BeiDou Galileo BeiDou GLONASS GLONASS BeiDou BeiDou Samp...

Page 29: ...e 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1kHz at 80 MHz to 6 GHz 30 V m PM 200 Hz square at 380 MHz to 385 MHz 30 V m PM 200 Hz square at 390 MHz to 395 MHz 3 V m PM 200 Hz s...

Page 30: ...o 150 Hz 3 x 5 h Shockb EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 10 g 11 ms 3 x 6 shocks saw tooth Weight 1540 gr Degree of protection EN 60529 Enclosure IP66...

Page 31: ...Discharge ETSI European Telecommunications Standards Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software HV High Voltage IEC International Engineering Consortium IC I...

Page 32: ...work Voltage SN Serial Number SNMP Simple Network Management Protocol WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment WLAN Wire...

Page 33: ...cy Approvals and Standards Compliance updated 3 3 2 Front Side Label callouts reversed order 3 5 Led Indicatiors illustration added 4 2 Factory Reset moved from old chapter 3 6 4 5 Cooling illustratio...

Page 34: ...Westermo Metallverksgatan 6 SE 721 30 V ster s Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 22901 REV D 2021 10 Westermo Network Technologies AB Sweden...

Reviews: