background image

www.westermo.com

         

  

               

                            

Ibex-RT-610 Series

EN 50155 WLAN 802.11ac Dual Concurrent Access Point

Summary of Contents for Ibex-RT-610 Series

Page 1: ...www westermo com Ibex RT 610 Series EN 50155 WLAN 802 11ac Dual Concurrent Access Point ...

Page 2: ...3 Product Description 11 3 1 Product Description 11 3 2 Available models 12 3 3 Hardware Overview 12 3 3 1 Frontside Overview 12 3 3 2 Front Side Label 12 3 3 3 Rear Side Label 13 3 3 4 Interface Ports View 13 3 4 Connector Information 14 3 4 1 Power Input Connection 14 3 4 2 Ethernet Ports 14 3 4 3 Antenna Ports 15 3 5 LED Indicators 16 3 6 Dimensions 16 4 Installation 18 4 1 Mounting 18 4 2 Fact...

Page 3: ...www westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This p...

Page 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No person...

Page 5: ...g conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur when connected to a power supply WARNING PROTECTIVE FUSE ...

Page 6: ...temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard This product complies with Touch Temperature Limits throughout its operational temperature range CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order t...

Page 7: ...hould not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed of correctly you will help to reduce hazardous substances and prevent potenti...

Page 8: ...tion EN 61373 category 1 class A and B EN 50125 3 Outside the track Insulation Coordination and test EN 50124 1 Railway applications Insulation coordination EN 50155 Railway applications Electronic equipment used on rolling stock Radio communication ETSI EN 300 328 Wideband transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using wide band modulation techniques ...

Page 9: ...ease the separation between the unit and receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help NOTE This product contains FCC IDs TK4WLE1216V520 and TK4WLE600VX 2 5 3 United States AREMA The product has been tested according to AREMA Part 11 5 1 environmental class J and D an...

Page 10: ...ity Hereby Westermo declares that this product is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European Conformity and the UK Conformity Assessment markings 10 Ibex RT 610 Series ...

Page 11: ...10 access point is designed to withstand tough environmental conditions and can be remotely managed using web browser or SNMP management tools Integrating hardware software and network design support tools this router platform offers advanced capabilities the lowest total cost of ownership and will create the most reliable and resilient networks The access point is engineered to maintain uninterru...

Page 12: ...f available models 3 3 Hardware Overview 3 3 1 Frontside Overview DC OPR ERR X1 X2 1 4 2 3 5 6 7 No Description 1 Gigabit Ethernet ports X1 and X2 2 Protective earth terminal 3 Power input DC 4 Front side label 5 Warning symbol for surface temperatures above 60 C 6 Antenna ports A1 to A4 B1 to B2 7 LED indicators Table 3 Location of interface ports and LED indicators 3 3 2 Front Side Label Ibex RT...

Page 13: ...n code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week Table 4 Front side label 3 3 3 Rear Side Label Type Ibex RT xxx xx EU IP66 Art No xxx xxxxxx NPN xxxxxx Max current 0 6A Power 24VDC 30 Country of origin Switzerland FCC IC e label http ip address Default IP 192 168 1 20 Westermo Neratec AG Postfach 83 CH 8608 Bubikon Figure 4 Rear side label content 3 3 ...

Page 14: ... Table 6 M12 A coded 4 pin male power connector according to IEC 61076 2 101 NOTE If the product is powered by PoE the protective dust cap which is part of the delivery must be closed to protect the power interface from water or dust ingress 3 4 2 Ethernet Ports The product includes two Ethernet ports X1 and X2 which supports auto negotiated 10 Mbit s 100 Mbit s and 1000 Mbit s operation Automatic...

Page 15: ...vice mode B 1 DC 2 DC 3 DC 4 DC 5 DC 6 DC 7 DC 8 DC Table 8 Ethernet PoE connection on X2 LV model only NOTE PoE is supported on X2 for the LV product variant only NOTE If the Ethernet function is not used the protective dust cap which is part of the delivery must be closed to protect the interface from water or dust ingress 3 4 3 Antenna Ports The antenna connectors are identified on the product ...

Page 16: ...y unused antenna ports must be properly terminated with 50 Ohm otherwise the product might be damaged when power is applied to a non terminated antenna port NOTE To ensure specified IP protection suitable QMA connectors cables and terminations must be used 3 5 LED Indicators DC OPR ERR X1 X2 Figure 5 LED indicators LED Description DC Power status OPR Operation status ERR Error status X1 Ethernet s...

Page 17: ...195 4 67 92 180 9 7 7 7 111 4 41 22 7 18 35 31 30 5 19 4 29 29 36 8 5 Figure 6 Dimensional drawing Ibex RT 610 Series 17 ...

Page 18: ... to ensure proper heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be covered by a protective cap delivered with the product tightened to the specified torque in order to fulfill the specified ingress protection code 4 2 Factory Reset To reset the product into factory ...

Page 19: ...ross section of at least 4 mm2 shall be used The grounding wire is set below the rip lock washer The nut is fixed for good reliable grounding contact The tightening torque of the grounding nut should not exceed 10 Nm X1 X2 DC Figure 7 Earth connection NOTICE Do not use equipment without protective earth connection 4 4 Connection of Cables Recommended tightening torque for the M12 connectors is 0 6...

Page 20: ...irflow is not blocked and that there is enough spacing around the product Figure 8 Installation with reduced natural convection airflow Figure 9 Installation with natural convection airflow When operating the product at high ambient temperatures it is recommended to mount the product to a metallic base plate to improve the heat dissipation The base plate increases the surface to spread the heat Fi...

Page 21: ...arms Improve installation conditions or RF parameters in case of any temperature alarms 4 6 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement product and reconnect all cables observing the instructions in Connection of Cables MTTR Mean Time To Repair i e time for replacement of product is 10 minutes CAUTION HOT SURFACE Be aware that the surfac...

Page 22: ...t 72 VDC 8 mA2 at 110 VDC Startup currenta 2 x nominal current Polarity Reverse polarity protected Redundant power input No Conductor cross section flexible 0 5 mm AWG 20 Cable temperature rating 40 to 70 C Shielded cable Not required aRecommended external supply current capability for proper startup PoE PoE powered product Ibex RT 610 LV only on X2 Connector M12 X coded female Device mode A and B...

Page 23: ...hernet cable shield itself is connected to protective earth Antenna WLAN A1 to A4 B1 to B2 Connector QMA female Direction Transmit and receive Cabling 50 Ohm coaxial cable and WLAN antenna required Conductive chassis Yes WLAN interface 4x4 MU MIMO for 5GHz 802 11ac Access Point 2x2 MIMO for 2 4GHz 802 11ac Access Point WLAN frequency bands 2 400 to 2 4835 GHz 5 150 to 5 350 GHz 5 470 to 5 725 GHz ...

Page 24: ...t must be terminated with 50 Ohm terminations NOTICE To avoid damages on the antenna interfaces ensure that the far end side of the antenna cable and or the antenna itself is connected to protective earth 24 Ibex RT 610 Series ...

Page 25: ...9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 25 V m 80 AM 1kHz at 80 MHz to 1 GHz 20 V m 80 AM 1 kHz at 1 GHz to 2 7 GHz 3 V m 80 AM 1 kHz at 2 7 GHz to 6 GHz 30 V m PM 200 Hz square at 380 MHz to 385 MHz 30 V m PM 200 Hz square at 390 MHz to 395 MHz Conducted RF immunity EN 61000 4 6 DC power port 10 V 80 AM 1 kHz from 0 15 to 80 MHz Ethernet ports Antenna ports Radiated RF emi...

Page 26: ...150 Hz 3 x 5 h Shockb EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 20 g 11 ms 3 x 6 shocks saw tooth Weight 1450 gr Degree of protection EN 60529 Enclosure IP66c Cooling Convection Pollution degree EN 62368 1 PD2 Conformal coating type IPC A 610 Electronic modules AR Acrylic aRefer to Safety and Regulations chapter regarding touch temperature bThe power and Et...

Page 27: ...ic Discharge ETSI European Telecommunications Standards Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software HV High Voltage IEC International Engineering Consortium IC Industry Canada ID Identification I O Input Output IP Ingress Protection ISO International Standardization Organisation LAN Local Area Network LED Light Emitting Diode LV Low Voltage MIMO Multiple In...

Page 28: ...twork Voltage SN Serial Number SNMP Simple Network Management Protocol WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment WLAN Wireless Local Area Network Table 12 Abbreviations and terms 28 Ibex RT 610 Series ...

Page 29: ...pliance updated 3 3 2 Front Side Label callouts reversed order 3 5 Led Indicatiors illustration added 4 2 Factory Reset moved from old chapter 3 6 4 5 Cooling illustrations updated Rev C 2021 05 2 5 5 Europe Simplified Declaration of Conformity updated text and figure 4 2 Earth connection updated Figures 4 7 8 and 9 updated Rev B 2020 10 Updated illustrations Rev A 2020 08 First revision Ibex RT 6...

Page 30: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 2290 REV D 2021 10 Westermo Network Technologies AB Sweden ...

Reviews: