2.2
Wiring Power Inputs
The Power input port is located at the bottom side, and provides 2 power input
connections in one 4-pin removable terminal block. The power port support polarity
reverse protection; the Switch won’t start if wrong polarity applied. The wiring
architecture please refers to below figure.
Wiring the Power Inputs
1.
Insert the positive and negative wires into the V+ and V- contact on the terminal
block connector.
2.
Tighten the wire-clamp screws to prevent the power wires from being loosened.
3.
Connect the power wires to suitable AC/DC Switching type power supply. The PMI-
110-F2G provides Power over Ethernet function and is compliant with IEEE802.3af/
IEEE802.3at standards; therefore, the input DC voltage should be in the range of DC
46V to DC 57V.
For the safety issue, turn off AC power input source before connecting the AC/DC Power
supply module and the terminal block connectors. Besides, don’t turn-on the source of
AC/DC power module and make sure all connections were well done then power on the
AC source to powering the Switch device. Otherwise, your screwdriver blade may
inadvertently short your terminal connections to the grounded enclosure and cause
damage.
Notes:
Use the
UL Listed LPS Power supply
with output Rating 46~57V Vdc, minimum
2.5A currents. Here, we recommended using DC 48V as the operating voltage. It is
recommended to use 48vdc power supply.
Summary of Contents for PMI-110-F2G
Page 1: ...1 PMI 110 F2G User s Manual Version 3 0 Industrial Managed PoE Switch ...
Page 5: ...1 5 2 Westermo Private MIB 234 5 3 Revision History 235 ...
Page 19: ...15 ...
Page 168: ...164 4 8 3 DSCP Queue Mapping 4 8 4 CLI Commands of the Traffic Prioritization ...
Page 193: ...189 ...
Page 234: ...230 Note No CLI command for this feature ...
Page 240: ...236 ...