17
2.4
Wiring the Digital Input (DI)
The Digital Input (D.I.) contacts are in the bottom side of the device as shown in below
figure.
It accepts one external DC type signal input and can be configured to send alert
message through Ethernet when the signal is changed. The signal may trigger and
generated by external power switch, like as door open trigger switch for control cabinet.
Note:
the DI accepts DC type signal and supports isolated input circuit with Digital High
Level input DC 11V~30V and Digital Low Level input DC 0V~10V. Do not apply voltage that
higher than the specification; it may cause internal circuit damage or a wrong action of DI.