RT-610 HV/LV User Guide
Page 29 (31)
4.2.2 Factory Reset Procedure
The Factory Reset is performed with a factory reset adapter that is connected to one of the Ethernet ports during
the start-up.
Step
Description
1.
Plug the factory reset adapter to one of the Ethernet interfaces.
2.
Power the device
3.
Wait until factory reset adapter is detected. This is indicated by a YELLOW operation LED in
combination with a RED status LED
4.
Remove factory reset adapter within 15 seconds
5.
A successful initiation of a factory Reset is indicated by a YELLOW BLINKING operation LED in
combination with a RED BLINKING failure LED
Table 19 Factory reset procedure
After successful factory reset, the dust cap must be closed to ensure the IP requirements.