5. Specifications
5.1. Interface Specifications
DC, Power port
Rated voltage
a
24 to 110 VDC
Operating voltage
b
16.8 to 143 VDC (14.4 to 154 VDC for 100 ms)
Rated current
Max 670 mA at 24 VDC, max 160 mA at 110 VDC
Rated frequency
DC
Inrush current, I²t
Viper-x20 units: 100 mA²s at 24 VDC, 140 mA
2
s at 110 VDC
Viper-x20-T4G units: 110 mA
2
s at 24 VDC, 140 mA
2
S at 110 VDC
Startup current
c
Max 1,37 A at 16.8 VDC
Polarity
Reverse polarity protected
Redundant power input
Yes
Isolation
To all other ports
Circuit type
Secondary circuit hazardous voltage, OVC II
Connector
4-pin, male, M12, A-coded, recommended Westermo cables:
3146-1106 for 1.5 m
3146-1107 for 5 m
Cable size
M12, recommended power cable area 0.5 mm² (minimum 0.25 mm²),
which correlates to AWG 21 or larger
Cable dimensions depend on choice of M12 connector
Cable temperature rating
For minimum temperature rating of the cable to be connected to the field
wiring terminals: -40 to +70 °C
a
Also referred to as nominal voltage in EN/IEC 61010-1
b
Also referred to as nominal input including fluctuations in EN/IEC 61010-1
c
Recommended external supply current capability for proper startup
18
Viper 20A Series