9

General description 

WMarine10 is a photovoltaic charge regulator for leaden electrochemical batteries either sealed (SEAL) or 
flooded lead acid (FLOOD). In fig. 1 there is a scheme principle of WMarine10. 
 

 

V

PAN 

3

I

PAN

I

charge 

MICRO -

CONTROLLER

 

Buck-bust 

converter

 

V

BATT 

I

LOAD 

 

Fig. 1 Block diagram 

4- Charge circuit: it adapts V

PAN

 and I

PAN

 (respectively voltage and current of the PV module) so to search the 

condition in which the power that is given by the PV module is maximum, thus realizing the MPPT 
(

Maximum Power Point Tracking

). In addition, it manages the battery charge by reducing the current sent 

towards the battery when the battery V

BATT

 exceeds its charge voltage (V

ch

). 

5- Circuit for load control: it turns on/off the load according to the program set by the user and it provides to 

load detachment in case of discharged battery, overload or short-circuit on the load. 

6- Microprocessor: it controls the whole circuit, it measures currents and voltages of PV module, battery and 

load and it shows them on the display. 

Summary of Contents for WMarine10

Page 1: ...tione carico selezionabili rendono il WMarine10 la soluzione completa in molte applicazioni ad esempio per alimentare telecamere che debbono funzionare solo di giorno oppure per alimentare lampeggiatori o segnalazioni stradali che debbono funzionare solo di notte o per alimentare sistemi di illuminazione che debbono funzionare per un determinato numero di ore per notte Il WMarine10 rileva lo stato...

Page 2: ...care la condizione in cui la potenza erogata dal modulo PV è massima realizzando quello che nella letteratura tecnica è indicato con la sigla MPPT Maximum Power Point Tracking Inoltre gestisce la ricarica della batteria riducendo la corrente erogata verso la batteria nelle condizioni in cui la tensione VBATT supera la sua tensione di ricarica Vch 2 Circuito per il controllo del carico accende speg...

Page 3: ...zionare Impiegare sezioni di cavo appropriati come indicato nella tabella di fig 2 3 Il WMarine10 riconosce automaticamente la tensione nominale di batteria 12V o 24V e adegua di conseguenza le sue soglie di funzionamento L utente deve però configurare il tipo di batteria in uso per adeguare la corretta tensione di ricarica Vch Si deve impostare la configurazione SEAL se si usano batterie ermetich...

Page 4: ...atore dell energia in KWh consumati dal carico E possibile azzerare questo contatore premendo contemporaneamente i pulsanti per 2 secondi Tasto Alla pressione del tasto si ritorna alla pagina principale Fig 3 Pagine visualizzazioni misure Configurazione del sistema Si accede alle pagine di configurazione del WMarine10 mantenendo premuti contemporaneamente per almeno 2 secondi i tasti Pagina config...

Page 5: ...entare nuovamente il carico e esce da questo stato se è sta eliminata la causa che ha generato il sovraccarico E stata connessa la batteria con polarità invertite Rivedere il collegamento elettrico della batteria Interviene quando la temperatura interna del WMarine10 supera gli 80 C e disattiva la ricarica Si esce automaticamente da questa protezione quando la temperatura interna scende al di sott...

Page 6: ...ch funzione della temperatura di batteria Tbatt Vtadj 24mV C 48mV C Tensione di low battery impostabile Vlb 10 8V 11 4V default 12 2V 21 6V 22 8V default 24 4V Tensione uscita low battery a 25 C programma SEAL Vout_lb 13 4V 27 8V Tensione uscita low battery a 25 C programma FLOOD Vout_lb 13 8V 28 6V Tensione rilevazione giorno impostabile Vday 1 9V 4 4V default 9 6V 1 9V 4 4V default 9 6V Tensione...

Page 7: ...si dalle istruzioni da noi fornite La garanzia decade altresì in caso di danni derivanti da trasporto e o cattiva conservazione del prodotto causa di forza maggiore o eventi catastrofici gelo per temperature inferiori a 20 C incendio inondazioni fulmini atti vandalici ecc Tutte le sopraccitate garanzie sono il solo ed esclusivo accordo che soprassiede ogni altra proposta o accordo verbale o scritt...

Page 8: ...he proper solution in several applications i e to power supply video cameras that have to work only during the day or to power supply flashing systems road signs that have to work only during night or to power supply lighting systems that have to work only for a certain number of hours during night WMarine10 detects the day night status according to the PV module s voltage therefore it is not nece...

Page 9: ...le so to search the condition in which the power that is given by the PV module is maximum thus realizing the MPPT Maximum Power Point Tracking In addition it manages the battery charge by reducing the current sent towards the battery when the battery VBATT exceeds its charge voltage Vch 5 Circuit for load control it turns on off the load according to the program set by the user and it provides to...

Page 10: ...d it begins to work Use proper cable sections as indicated in fig 2 3 WMarine10 recognizes automatically the battery nominal voltage 12V or 24V and it adapts consequently its working thresholds The user must configure the kind of battery in use to adequate the right charge voltage Vch You have to set SEAL configuration if you use VRLA or GEL sealed batteries while you have to choose FLOOD configur...

Page 11: ...t is currently delivered to the load in watt button It displays the energy counter in KWh consumed by the load It is possible to reset this counter pressing simultaneously the buttons for 2 seconds button Pressing the button you go back to the main page Fig 3 Display pages of measures System configuration You can go to the configuration pages of WMarine10 pressing simultaneously for at least 2 sec...

Page 12: ...n the load It exits from this condition if the cause that generated the overload has been eliminated The battery was connected with inverted polarities Check the electrical connections of the battery You have this error when internal temperature of WMarine10 exceeds 80 C and deactivates the charge You exit automatically from this protection when the internal temperature goes below the threshold of...

Page 13: ...8mV C Low battery voltage it can be set Vlb 10 8V 11 4V default 12 2V 21 6V 22 8V default 24 4V Output voltage from low battery at 25 C SEAL program Vout_lb 13 4V 27 8V Output voltage from low battery at 25 C FLOOD program Vout_lb 13 8V 28 6V Solar modules threshold voltage for day detection settable Vday 1 9V 4 4V default 9 6V 1 9V 4 4V default 9 6V Solar modules threshold voltage for night detec...

Page 14: ...ntions that are different from the instructions supplied by us Warranty is void if damage is also caused by transport and or bad storage of the product force majeure or catastrophic events frost for temperatures 20 C fire flooding lightning vandalism and so on All the above guarantees are the sole and exclusive agreement which supersedes any proposal or agreement whether written or oral and any ot...

Reviews: