an AC Power Plug as there is no international standardization. When installing an
AC Power Plug onto the AWG 18-3 Power Cord, the following is the identity of the 3
Color Coded Conductors;
•
Green – Ground
•
White – Neutral
•
Black – Live
Care must be taken to insure the proper installation of an AC Power Plug, and if there
is any question, contact your distributor or Western Instruments. If an AC Plug in not
installed before use, any warranty is void.
7. Pull Test / Calibration
When performing a 20 Pound (9 kg) Pull Test, ensure the contact feet are flat as
possible to the Pull Test Bar (W-PT
®
), which ensures as much magnetic attraction as
possible. If a Yoke fails a pull test, it should be sent to an authorized repair facility for
Contact Foot Dressing.
Warranty
Western Instruments warrants its products, against defects in materials and workmanship for a
period of 1year from receipt by the end user. If Western Instruments receives notice of such
defects during the warranty period, Western Instruments will either, at it’s option, repair, replace,
or condemn products that prove to be defective. Consumable items, such as Batteries are
warranted for 30 days, from receipt by the end user.
Any warranty is void if the unit has been modified in any way, or if it has been repaired by an
unauthorized agency. The end user agrees that any equipment’s disposition, when returned for
warranty work, is at the full discretion of Western Instruments as to whether a claim is under
warranty, or due to misuse. Western Instruments warranty shall overlook normal wear, however
does not include operation outside the environmental specification of the product. All warranty
work is FOB Western Instruments, and any returned units shall include a written description, by
the end user, of the fault.
Western Instruments makes no other warranty, either expressed or implied, with respect to this
product. Western Instruments specifically disclaims any liability arising form the use of this
equipment. For the correct use of the product, refer to the Operating Instructions, furthermore
we recommend instructional training to CGSB, ASNT, or other regulatory authority
qualifications. Western Instruments highly recommends the end user exercise all possible
safety precautions, including use of protective equipment, while operating this or other industrial
equipment.
Specifications:
Model: WC-6X2 or WC-6X2K
Voltage: 115VAC or 230VAC
Frequency: 50 or 60 Hz
Current: AC – 7.0 Amps
@
115 Volts or 4 Amps
@
230 Volts
Capacity: <20 Pounds (9.2 Kg)
Pole Spacing: 0 – 11” (0 – 280mm)
Weight: 7.2 Pounds (3.3 Kg)
WC-6X2 Operation Manual