91
Replacement of the Program Chip
16 Replacement of the Program Chip
Refer replacement of the program chip only to qualified personnel.
Proceed as follows:
1. Before replacing the program chip, write down all machine settings. To this end, switch
the System--machine off, press the Menu key while switching the machine on once again.
Keep the Menu key pressed until the new program version is displayed. Note down all
machine settings previously selected, such as e.g. language, machine type, interface etc.
2. Disconnect the System--machine and make it currentless.
3. Open the control--unit box and remove the old program chip (chip with adhesive label
„SM2 Plus XX.XX“). Use appropriate tools, in order not to damage the strip conductors on
the main circuit card. If necessary, remove the main circuit card.
4. Put in the new program chip with the notch upwards.
XX.
XX
SM2
Plus
5. Close the control--unit box.
6. Connect the System--Machine. When starting the machine, the display shows the new
program version. In case the message „Fault Memory error“ is displayed, disconnect the
machine once again.
7. Press the three keys „Automatic“, „Cleaning“ and „Menu“ simultaneously and connect
the System--Machine. Keep them pressed until the display shows the number of the
program version. Carry out a new programming of the Setup.
8. Carry out new calibration.
9. Check portion values, milk values and machine values.
Summary of Contents for 7163-9001-044
Page 2: ......
Page 37: ...37 Connecting the System Machine to the Feeding Computer ...
Page 96: ......
Page 103: ...N PE distribution board motherboard motherboard ...
Page 111: ...Ersatzteillisten spare part lists für Kälbertränkeautomat for Calf Feeder ...
Page 112: ......
Page 114: ......
Page 116: ......
Page 118: ......
Page 124: ...40813 01 02 3 6 9 9 12 15 18 21 24 24 24 27 30 33 ...
Page 130: ...24 28 15 21 33 30 12 99262 11 02 27 17 18 19 2 1 3 4 5 36 37 ...
Page 138: ......
Page 140: ...40605 10 01 3 6 9 12 15 18 21 24 33 36 30 39 42 45 27 54 48 51 ...
Page 142: ... ...