12
Operation
-2-
the digital spirit level unmoved until the
number “
-2-
“ appears on
the display and starts flashing.
4. Horizontally flip over
the digital spirit level
by 180º. Then press
the ON/OFF key (3)
once more. A few
seconds later the
num
ber “
-2-
“ flashes quickly on the display. Keep the digital spirit
level unmoved until the display returns to display the current
measuring value. The calibration process is finished.
5. Now you can use the unit or switch off with the ON/OFF key.
Technical Data
Batteries:
2x
LR03 (AAA)
Battery Life:
approx. 100 hours
Measuring Range:
0º
… +/- 90°
Resolution:
0.1°
Measuring Accuracy:
± 0.2°
Working Temperature:
-10° C to +50° C
Storing Temperature:
-20° C to +70° C
Dimensions:
416 x 50 x 21 mm
Weight (incl. Batteries):
approx. 300 g
Cleaning and Storing
Clean the digital spirit level with a smooth and dry linen cloth. If
necessary moisten it slightly.
Do not use any solvents, detergents, sharp edged objects and
the like for cleaning.
Store the unit on a dry place that is protected from dust and dirt.
Store it out of reach of children.