WarNiNg NOTE
Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  Occasional fumes 
from de ashing and re fuelling may occur.  However, persistent fume emission is potentially dangerous and must 
not be tolerated. If fume emission does persist, then the following immediate action should be taken: 

(a) 

Open doors and windows to ventilate room

(b) 

Let the fire go out or eject and safely dispose of fuel from the appliance

(c) 

Check for flue or chimney blockage and clean if required

(d) 

Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.   

 

If necessary seek expert advice.

The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be 
kept clean at all times.

iMPOrTaNT NOTEs
general
Before lighting the stove check with the installer that the installation work and commissioning checks described 
in the installation instructions have been carried out correctly and that the chimney has been swept clean, is 
sound and free from any obstructions. As part of the stoves’ commissioning and handover the installer should 
have shown you how to operate the stove correctly.

Use of fireguard
When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be 
used to prevent accidental contact with the stove.  The fireguard should be manufactured in accordance with BS 
6539.

Chimney cleaning 
The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood 
and other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a pro-
longed shutdown period.
If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to 
clear any soot falls which may have occurred due to the difference in combustion between the stove and the 
open fire.
In situations where it is not possible to sweep through the stove the installer will have provided alternative 
means, such as a soot door.  After sweeping the chimney the stove flue outlet and the flue pipe connecting the 
stove to the chimney must be cleaned with a flue brush.

hETas Ltd approval
This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level (single tick approval) for burn-
ing wood logs only as detailed in list of recommended fuels above. Approval does not cover the use of other fuels 
either alone or mixed the recommended fuels listed, nor does it cover instructions for the use of other fuels.

guarantee
Your new stove is covered by a five year guarantee against manufacturing defects. Your receipt documents is the 
date of purchase. The guarantee does not cover damage caused by faulty operation such as overheating or the 
stove being incorrectly connected, or damage which occurs as a result of external physical force.
The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty 
or the installation/dismantling of the stove in connection with repairs under warranty.
Warning! Any unauthorised modification of the appliance is forbidden.
Only replacement parts recommended by Westfire ApS should be used for repairs. 

Summary of Contents for WF ONE

Page 1: ...WESTFIRE WF SERIES ONE TWO 1 the art of danish engineering WF series one Two INSTALLATION MANUAL AND OPERATING INSTRUCTIONS ...

Page 2: ...WESTFIRE WF SERIES ONE TWO This manual refers to the stove type listed above which has been tested in accordance with EN13240 WF series ONE Two Westfire WF SERIES TWO Westfire WF SERIES ONE ...

Page 3: ...e conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recom mendations given in British Standards BS 8303 BS 6461 and BS 7566 as an alternative means to achie...

Page 4: ...utlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 160 mm x 160 m...

Page 5: ...and are suitable to be installed on a 12mm non combustible plate such as Westfire 12mm glass plates or 20mm slate plates Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to...

Page 6: ...ITIONS WF SERIES ONE TWO WF SERIES ONE TWO Pedestal Distance from rear to centre of top flue exit 120 mm 120 mm Distance from floor to centre of rear flue exit 454 mm 734 5 mm Distance from floor to centre of external air intake 174 mm 454 5 mm WESTFIRE SERIES ONE TWO PEDESTAL ...

Page 7: ...od deal of smoke and odour it is therefore important that the first time you light your stove the room should be well ventilated During the process it is important to open and close the stove door periodically every 30mins during the first couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened...

Page 8: ...e Close the air damper and the stove door and call 999 or your local fire department If your stove is overheating all air sliders and the door must be closed and left until the stove has returned to nominal temperature Basic Positions of air controls during operation You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly as factors such ...

Page 9: ...ng then close the secondary air valve to its operational position On returning to the stove in the morning the fire will have burn out reload with some paper or firelighter and some kindling and open all the slider fully to relight quickly Beware as the ash bed will have hot embers Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is...

Page 10: ... height of the chimney in relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air control setting to the minimum and tightly close the doors of the stove This should cause the chimney f...

Page 11: ...or smokeless fuels and a minimum of twice a year for wood and other fuels It is important that the flue connection and chimney are swept prior to lighting up after a pro longed shutdown period If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the s...

Page 12: ...WESTFIRE WF SERIES ONE TWO 12 RE INSTALLING BRICK SETS ...

Page 13: ...WESTFIRE WF SERIES ONE TWO 13 ...

Page 14: ...trol zone You must purchase a smoke control version of the Westfire stove which is altered slightly to comply with regula tions This stove can not be altered if it is it will not comply with regulations Westfire smoke control stoves should not be burnt with the door left open Operating your stove in a smokeless zone Firelighters should ideally be used when lighting the stove Never use mentholated ...

Page 15: ...Split logs lengthways for drying Use logs no bigger than about see table below Stove Log length weight WF Uniq 17 18 19 10cm x20cm 1 4KG WF Uniq 15 16 20 10cm x 20cm 1 4KG WF Uniq 23 10cm x 33cm 1 5KG WF Uniq 21 10cm x 20cm 1 4KG WF Uniq 26 27 28 10cm x 20cm 1 4KG WF Uniq 32 10cm x 40cm 1 6KG WF Series ONE 10cm x 30cm 1 4KG WF Series TWO 10cm x 40cm 1 6KG Ensure logs are absolutely dry less than 1...

Page 16: ...F SERIES ONE TWO 16 Tømrervej 3 DK 6800 Varde phone 45 7522 5352 fax 45 7522 1352 www westfire dk e mail info westfire dk WESTFIRE 2011 We cannot be held responsible for misprints 17392 Mediegruppen Reklamebureau ...

Reviews: