9

door operation
When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from 
possible heat. The handle twists right away from the fire. When shutting the door push the door closed and twist 
left until the handle firmly closes.

WOOd fUEL

iMPOrTaNT: Never use toxic wood such as chipboard, impregnated or painted wood.
Good quality is the most important factor in your stove working efficiently and cleanly. Always use dry firewood. 
The dryness of the firewood plays an important role since the use of wet wood results in poor fuel economy and 
may cause a tarry sooty film on the internals of the stove.

Newly cut wood contains 60–70% water, making it totally unsuitable for use as firewood.
Newly cut wood should be stacked and air dried under cover for two years before being used as firewood.

sOLid sMOKELEss fUELs-   The WESTFIRE WF SERIES ONE & TWO stoves are suitable for use with good quality 
smoke less fuels. The stove will burn best when burning wood. HOUSE COAL AND PETROLEUM COKE ARE NOT 
SUITABLE FOR USE ON THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE.

Overnight burning
Westfire SERIES ONE & TWO, are designed to burn wood and can burn quality smokeless fuels. 
Wood burns more efficiently and cleanly if is burnt hotter. Westfire do not recommend that their stoves are burnt 
overnight for this reason.
As a night time regime we recommend that the fire is loaded when hot and burnt for five minutes with the 
secondary air slider fully open until the new wood has taken and is burning, then close the secondary air valve to 
its operational position.
On returning to the stove in the morning the fire will have burn out, reload with some paper or firelighter and 
some kindling and open all the slider fully to relight quickly. Beware as the ash bed will have hot embers. 

Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.

Maintenance
WESTFIRE SERIES ONE & TWO stove needs to have the ash removed from the stove at regular intervals. Make 
sure the stove is completely cold before cleaning out ash (embers can remain hot for over 24 hours). To operate 
riddling grate push and pull riddling arm on base right of stove using tool provided with the stove.
To clean the outside of the stove use a dry cloth. 
annual service
The inside of the stove should be serviced /cleaned once a year. To clean the inside, remove all ash, soot and tar 
residue from the combustion chamber. Remove insulated chamber panels and baffle, dirt and soot will collect 
behind it and this must be cleaned out.  Check the quality of all insulated panels and replace any which are 
damaged or cracked, replace stove door rope cord in the door. Check glass is correctly positioned.
The stove, the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The 
chimney should also be checked for blockages before relighting the stove if it has not been used for an extended 
period of time.
The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, may be 
repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste.

Summary of Contents for WF ONE

Page 1: ...WESTFIRE WF SERIES ONE TWO 1 the art of danish engineering WF series one Two INSTALLATION MANUAL AND OPERATING INSTRUCTIONS ...

Page 2: ...WESTFIRE WF SERIES ONE TWO This manual refers to the stove type listed above which has been tested in accordance with EN13240 WF series ONE Two Westfire WF SERIES TWO Westfire WF SERIES ONE ...

Page 3: ...e conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recom mendations given in British Standards BS 8303 BS 6461 and BS 7566 as an alternative means to achie...

Page 4: ...utlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 160 mm x 160 m...

Page 5: ...and are suitable to be installed on a 12mm non combustible plate such as Westfire 12mm glass plates or 20mm slate plates Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to...

Page 6: ...ITIONS WF SERIES ONE TWO WF SERIES ONE TWO Pedestal Distance from rear to centre of top flue exit 120 mm 120 mm Distance from floor to centre of rear flue exit 454 mm 734 5 mm Distance from floor to centre of external air intake 174 mm 454 5 mm WESTFIRE SERIES ONE TWO PEDESTAL ...

Page 7: ...od deal of smoke and odour it is therefore important that the first time you light your stove the room should be well ventilated During the process it is important to open and close the stove door periodically every 30mins during the first couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened...

Page 8: ...e Close the air damper and the stove door and call 999 or your local fire department If your stove is overheating all air sliders and the door must be closed and left until the stove has returned to nominal temperature Basic Positions of air controls during operation You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly as factors such ...

Page 9: ...ng then close the secondary air valve to its operational position On returning to the stove in the morning the fire will have burn out reload with some paper or firelighter and some kindling and open all the slider fully to relight quickly Beware as the ash bed will have hot embers Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is...

Page 10: ... height of the chimney in relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air control setting to the minimum and tightly close the doors of the stove This should cause the chimney f...

Page 11: ...or smokeless fuels and a minimum of twice a year for wood and other fuels It is important that the flue connection and chimney are swept prior to lighting up after a pro longed shutdown period If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the s...

Page 12: ...WESTFIRE WF SERIES ONE TWO 12 RE INSTALLING BRICK SETS ...

Page 13: ...WESTFIRE WF SERIES ONE TWO 13 ...

Page 14: ...trol zone You must purchase a smoke control version of the Westfire stove which is altered slightly to comply with regula tions This stove can not be altered if it is it will not comply with regulations Westfire smoke control stoves should not be burnt with the door left open Operating your stove in a smokeless zone Firelighters should ideally be used when lighting the stove Never use mentholated ...

Page 15: ...Split logs lengthways for drying Use logs no bigger than about see table below Stove Log length weight WF Uniq 17 18 19 10cm x20cm 1 4KG WF Uniq 15 16 20 10cm x 20cm 1 4KG WF Uniq 23 10cm x 33cm 1 5KG WF Uniq 21 10cm x 20cm 1 4KG WF Uniq 26 27 28 10cm x 20cm 1 4KG WF Uniq 32 10cm x 40cm 1 6KG WF Series ONE 10cm x 30cm 1 4KG WF Series TWO 10cm x 40cm 1 6KG Ensure logs are absolutely dry less than 1...

Page 16: ...F SERIES ONE TWO 16 Tømrervej 3 DK 6800 Varde phone 45 7522 5352 fax 45 7522 1352 www westfire dk e mail info westfire dk WESTFIRE 2011 We cannot be held responsible for misprints 17392 Mediegruppen Reklamebureau ...

Reviews: