On completion of the installation allow a suitable period of time for any fi re cement and mortar to dry out, when 
a small fi re may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and 
emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left 
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be 
used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to 
use a fi reguard to BS 6539 in the presence of children, aged and/or infi rm persons.
 
Operating your stove – UNIQ 15,16, 20

Initial lighting
The heat-resistant paint on your stove will has to cure and harden the fi rst time you light your appliance. The 
curing process produces can produce a good deal of smoke and odour, it is therefore important that fi rst time you 
light your stove the room should therefore be well ventilated. During the process it is important to open and close 
the stove door periodically (every 30mins) during the fi rst couple of fi rings therefore preventing the door seal 
cord around the door from sticking and coming away from the door. Once the Heat-resistant paint has hardened; 
the stove door must be kept closed except when lighting the stove, adding fi rewood or removing ash in order to 
prevent fl ue gas from escaping.

Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use mentholated spirit, petrol or other fl am-
mable liquids). Lighting your stove fi re lighters will be more reliable and easier than paper.

To light your stove
1.  Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic fi relighters.
2.  Fully pull open the air slider (secondary air) and the air slider on ash pan (Primary air) it maybe necessary pull 

the ash pan drawer open 1cm as well)

3.  Light the fi relighters close the door.
4.  Once the fi re has caught, add two pieces of wood measuring approx 20cm with a combined weight of approx 

1.4kg and close the door.

5.  After approximately 10 minutes when the fi re is burning brightly shut the air control on the ash pan.
6.  After approximately another 10 minutes close the secondary air slider by 50% (25% on smoke control mod-

els), for the stove to burn cleanly plenty of secondary air is needed, do not be tempted to shut the fi re down 
too early as this may cause smoke. At nominal heat output, expect to refuel your stove approximately once 
an hour.

WF 15, WF 16 and WF 20 are all equipped with a control valve for secondary air designed to ensure a plentiful 
supply of oxygen during fi ring. When lit, the stove will get very hot and due care must therefore be exercised. 
Please use a glove when operating levers and dampers.

RE-FUELING
To re-fuel in a the cleanest way.
Before refuelling open secondary air value fully, also open primary air slider fully (on ash pan) and leave for 
5 minutes. Open door gently, add two pieces of wood add two pieces of wood measuring approx 20cm with a 
combined weight of approx 1.4kg and close the door. Leave the air values open for 10 minutes to allow the fi re 
to reach a good temperature. Then close primary air valve (on ash pan) and slide secondary air value to 50% 
open (75% open on smoke control models). Once the fi re is hot the primary air slider can be closed fully.

In the event of a chimney fi re: Close the air damper and the stove door, and call 999 or your local fi re department.

If you stove is over heating close all dampers and door must be closed, and left until the stove has return to 
nominal temperatures’.

SMOKE CONTROL ZONES

Burning your stove in a smoke control zone.

The Westfi re 15, 16 and 20 are registered to burn in a smoke controlled area. Your must purchase a smoke control 
version which is altered slightly to comply with regulations. This stove can not be altered, if it is it will not comply 
with regulations.
 
Basic Positions of dampers during Operation
You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly, 
as factors such as the quality and height of your chimney, the quality of your fuel and the external conditions 
play a large role in your stove performance. It is easy to see whether the stove is functioning correctly; however 
incomplete combustion may lead to a build-up of hard, shiny soot on the inside of your stove and glass. 
To prevent sooting of the chamber and glass introduce secondary air, also check that your wood is dry.
It is important to check the draft conditions before lighting your stove. This may be done, for instance, by crum-
pling a piece of newspaper, placing it in the combustion chamber and lighting it. The draft conditions are good if 
the smoke is drawn away through the chimney.

CONTROLS on WESTFIRE UNIQ 15,16 & 20

Door operation
When opening the door of your Westfi re stove always wear the glove that is provided to protect your hand from 
possible heat. The handle twists right away from the fi re. When shutting the door push the door closed and twist 
left until the handle fi rmly closes.

WOOD FUEL
IMPORTANT:
 Never use toxic wood such as chipboard, impregnated or painted wood.
Good quality wood is the most important factor in your stove working effi ciently and cleanly. Always use dry 
fi rewood. The dryness of the fi rewood plays an important role since the use of wet wood results in poor fuel 
economy and may cause a tarry sooty fi lm on the internals of the stove.

Newly cut wood contains 60–70% water, making it totally unsuitable for use as fi rewood.
Newly cut wood should be stacked and air dried under cover for two years before being used as fi rewood.

SOLID SMOKELESS FUELS – Westfi re stoves are not tested for use with smokeless fuels – therefore we do not rec-
ommend the use of smokeless fuels with these stoves. PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS STOVE; 
ITS USE WILL INVALIDATE THE GUARANTEE.

UK

UK

Tertiary air ports: six ports at the rear of the combus-
tion chamber provide fresh preheated air to improve 
secondary combustion of gases

Door handle, twist right away from fi re. Wear protec-
tive glove when fi re is lit.

Ash pan: when lighting open primary air slider (behind 
handle on ash pan) and pull open the ash pan by 1cm.

Secondary air: the valve is placed below the ash pan. 
Pull out for more air and push in to reduce air. Once 
warm your stove will be controlled only from this 
valve.

Summary of Contents for WF15

Page 1: ... WF16 WF20 1 DANSK INGENIØRKUNST DK INSTALLATIONS OG BRUGSVEJLEDNING WF15 WF16 WF20 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS D INSTALLATIONS UND GEBRAUCHSANWEISUNG FR NOTICE D INSTALLATION ET D UTILISATION ...

Page 2: ...ing af Deres brændeovn er der en række love og bestemmelser i Bygningsreglementet der skal overholdes Disse bestemmelser kan man læse i Bygningsreglementet Bygningsreglementet siger at ved lukkede ildsteder skal brændbare gulve dækkes mindst 30 cm foran fyringsåbningen og mindst 15 cm til hver side Underlaget skal være af ikke brændbar materiale f eks stålplade glasplader klinker eller kunstskifer...

Page 3: ...rbrændingen sker på den rigtige måde Hvis Deres ovn indvendig får en belægning af hård blank sod er der tegn på en ufuldstændig forbrænding i så fald skal der tilføres mere sekundærluft Det er vigtig at man inden fyring kontroller trækforholdene det kan fx gøres ved at krølle et stykke avispapir sammen ligge det i brændkammeret og antænde det hvis røgen trækker fint ud gennem skorsten er trækforho...

Page 4: ...burning wood in a smoke control area PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room CHIMNEY Chimney Connection Flue Diameter 150mm 175cm2 IMPORTANT When installing the UNIQ 15 16...

Page 5: ... combustion air This is particularly necessary if the room is double glazed or a flue draught stabiliser is operating in the same room as the appliance The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Air inlets must be positioned in such a way that they cannot be blocked An ai...

Page 6: ... pieces of wood measuring approx 20cm with a combined weight of approx 1 4kg and close the door Leave the air values open for 10 minutes to allow the fire to reach a good temperature Then close primary air valve on ash pan and slide secondary air value to 50 open 75 open on smoke control models Once the fire is hot the primary air slider can be closed fully In the event of a chimney fire Close the...

Page 7: ...aft b check for blockages in the flue pipe chimney c check the height of the chimney in relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air control setting to the minimum and tightl...

Page 8: ...rick 6 fitted UK means such as a soot door After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush HETAS Ltd Approval This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level single tick approval for burning wood logs only as detailed in list of recommended fuels above Approval does not cover...

Page 9: ...le Kaminöfen von Westfire sind mit einer Rauchumlenkplatte ausgestattet sodass der Weg den der Rauch nimmt möglichst lang ist ANSCHLUSS AN SCHORNSTEIN Der Schornstein muss einen Durchmesser von mindestens 15 cm aufweisen was einer Öffnung von 175 cm entspricht Er muss zudem eine Höhe haben die ausreichend Zug gewährleistet und dafür sorgt dass es zu keiner Rauchbelästigung in unmittelbarer Nähe ko...

Page 10: ...unbefugten technischen Änderungen am Ofen Bei Reparaturen sind ausschließlich von der Fa Westfire ApS empfohlene Ersatzteile zu verwenden Das Rauchrohr ist mit einer Regulierklappe erhältlich die es ermöglicht den Schornsteinzug an Tagen mit starkem Wind zu regulieren Sie darf sich nicht vollständig schließen lassen d h der freie Durchgang muss mind 20 cm betragen Eine Verringerung des Schornstein...

Page 11: ...jours de grand vent La trappe ne doit pas se fermer complètement mais doit avoir une surface libre d au moins 20 cm2 sur la surface d ouverture totale du conduit Il est également possible d avoir d autres types de limitateurs de tirage par exemple en laissant entrer l air dans la cheminée sans passer par le poêle Les modèles WF15 WF16 et WF20 peuvent être raccordés au conduit de cheminée même lors...

Page 12: ...rseur de fumées Il peut arriver que l une des plaques Skamol se fende après avoir été heurtée trop violemment par un morceau de bois Cela n a pas d incidence sur la combustion ce qui n est pas le cas de l inverseur de fumées Lorsque les plaques Skamol sont si usées qu elles ne sont plus entières il est temps de les remplacer C est également le cas lorsque les plaques sont fendues à plusieurs endro...

Page 13: ...24 TØMRERVEJ 3 DK 6800 VARDE TELEFON 45 7522 5352 FAX 45 7522 1352 WWW WESTFIRE DK E MAIL INFO WESTFIRE DK WESTFIRE 2009 Der tages forbehold for trykfejl 14136 Mediegruppen Reklamebureau ...

Reviews: