SAFETY TIPS

OBSErVE THE FOLLOWInG: rEad and SaVE THESE InSTruCTIOnS

WarnInG: TO rEduCE THE rISK OF FIrE, ELECTrIC SHOCK, Or PErSOnaL InJurY, MOunT TO OuTLET BOX MarKEd 'aCCEPTaBLE FOr Fan SuPPOrT OF 35 LBS (15.9 KG) Or LESS' and uSE 

MOunTInG SCrEWS PrOVIdEd WITH THE OuTLET BOX and/Or SuPPOrT dIrECTLY FrOM BuILdInG STruCTurE. MOST OuTLET BOXES COMMOnLY uSEd FOr THE SuPPOrT OF LuMInarIES 

arE nOT aCCEPTaBLE FOr Fan SuPPOrT and MaY nEEd TO BE rEPLaCEd. COnSuLT a QuaLIFIEd ELECTrICIan IF In dOuBT

.

1.    Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
2.    Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3.    After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on
        the other side of the outlet box.
4.    Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting
        means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5.    Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6.    When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7.    Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 10 feet from the floor to the trailing edge of the blade.
8.    To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support. And use mounting screws provided with the outlet box.
        (Mounting must support at least 35 lbs.)
9.    Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10.  Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”.
11.  To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12.  If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13.  NEVER place a switch where it can be reached from a tub or shower.
14.  The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as
        those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15.  Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means
        cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

TOOLS REQUIRED

Phillips Screwdriver                Wire Cutters                Pliers                 Step Ladder

Summary of Contents for ETL-ES-GW-IndustrialWC-WH17

Page 1: ...trialWC WH17 Owner s Manual Manual del usuario Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia Net Weight 12 56 LBS Peso Neto 5 7...

Page 2: ...ou choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 10 feet from the floor to the trailing edge of the blade 8 To reduce the risk of fire electric shock or...

Page 3: ...cir el riesgo de incendios choques el ctricos o heridas personales este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador...

Page 4: ...the fan to wobble 2 pREPARING for installation Antes de la instalaci n Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alim...

Page 5: ...rte de montaje a la caja de embutir del techo can la torniller a suministrada con la caja embutir 3 4 MOUNTING OPTIONS OPCIONES DE MONTAJE Choose a MOUNTING OPTION Elija una OPCI N DE MONTAJE NORMAL D...

Page 6: ...je la esfera de la varilla vertical 1 de la varilla vertical 2 quitando el tornillo 3 2 3 1 EXTENDED DOWNROD OPTION OPCI N CON VARILLA VERTICAL M S LARGA 6 Slidedownrodball 1 offofdownrodandremovepin...

Page 7: ...against the downrod to secure the downrod ball Vuelva a instalar el pasador en la varilla vertical m s larga y deslice la esfera de la varilla hasta el extremo superior de la misma Vuelva a insertar e...

Page 8: ...tter pin nut lock washer and bolt from the yoke Insert the down rod into the yoke Install bolt 1 through yoke 2 and downrod Install lockwasher 3 and nut 4 and tighten Install cotter pin 5 Quitale la c...

Page 9: ...properly Tighten set screw in the lower canopy Alineeelinterruptordemarchaatr sdelahorquillaalagujeroparaelinterruptordemarchaatr scorrespondienteubicadoeneldoselinferior Desliceeldoselinferiorhaciaab...

Page 10: ...el ventilador hasta el soporte de montaje Gire el ventilador hasta que la muesca de la bola de la varilla vertical 1 calce sobre la saliente del soporte de montaje 2 De este modo tendr las dos manos l...

Page 11: ...bleado del control de pared 1 Conecte el cable negro marcado AC In L del control de pared con el cable negro de suministro de CA 2 Conecte el cable negro marcado To Motor L del control de pared con el...

Page 12: ...the mating holes of the canopy and tighten to secure the canopy to the mounting bracket Para ventiladores con varilla vertical deslice el dosel hacia arriba hasta el soporte de montaje El dosel tiene...

Page 13: ...laci n de las ALETAS 3 Install blades to top of motor using screws and washers See above drawing for reference 15 Instale las aletas en la parte superior del motor con los tornillos y arandelas de seg...

Page 14: ...de embutir usando los dos tornillos provistos Operations 0 Fan Speed OFF 1 Fan Speed HIGH 2 Fan Speed MEDIUM HIGH 3 Fan Speed MEDIUM 4 Fan Speed LOW Operaci n 0 Control de velocidad del ventilador AP...

Page 15: ...warm air off the ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort NOTE Turn off and wait for fan to stop before changi...

Page 16: ...scendente aleja el aire caliente del rea del ventilador de techo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad NOTA Apague el v...

Page 17: ...fied electrician Do not attempt to troubleshoot internal electrical connections yourself 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws wh...

Page 18: ...el ctricas internas 1 Compruebe para asegurarse de que todos los tornillos del alojamiento del motor est n ajustados no los apriete demasiado 2 Compruebe para asegurarse de que los tornillos que fijan...

Page 19: ...S GW IndustrialWC WH17 1 2 3 Description 1 Mounting Bracket 2 Blade 3 Wall Control 4 Hardware Pack No Descripci n 1 Soporte de montaje 2 Aleta 3 Control de pared 4 Torniller a 4 PARTS LIST LISTA DE RE...

Page 20: ...hting Philadelphia PA 19154 1029 U S A www westinghouselighting com WESTINGHOUSE and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghous...