Westinghouse Outdoor Power Equipment, LLC | 21
OPERATION
1.
Make sure the battery switch and the ECO MODE switch
are in the OFF position.
2.
Connect the black and red parallel cable leads to the
black parallel ports on each corresponding generator
control panel as shown below. Connect the black lead
to the left port, the red lead to the right port.
Note:
DO NOT connect two red leads or two black leads
into the same generator.
3.
Connect the green ground lead to the ground terminal
on each generator and tighten the nut.
4.
Start one of the generators and wait until the OUTPUT
READY LED illuminates.
5.
Start the second generator and wait until the OUTPUT
READY LED illuminates before connecting a load.
6.
Connect additional loads as described in Power
Management on page 18.
7.
Unplug all loads before stopping the generators.
TRANSPORTING
Weight hazard. Always have assistance when lifting the
generator.
• Allow the generator to cool a minimum of 30 minutes
before transporting.
• If operating on LPG, turn the propane tank valve to the
fully closed position.
• Disconnect the LPG/propane hose from the generator
and propane tank.
• Replace all protective covers on the generator control
panel.
•
Only use the generator’s fixed handle(s) to lift the unit
or attach any load restraints such as ropes or tie-down
straps. Do not attempt to lift or secure the generator by
holding onto any of its other components.
• Keep the unit level during transport to minimize the
possibility of fuel leakage or, if possible, drain the fuel
or run the engine until the fuel tank is empty before
transport.
• The generator wheels are only intended for hand
transport. The wheels are not suitable for towing the
generator either on or off-road.
• Use the extendable handle for one-person, hand
transport. To deploy the handle, push on the locking
button and pull on the handle until it’s fully extended.
To stow it, push on the locking button and push on the
handle until it’s fully retracted. Only extend or retract
the handle while the generator is OFF, stationary,
and resting on a horizontal surface. Do not use the
extendable handle to lift the generator entirely off the
ground, tow it, or up-end it.
Fire hazard. Do not up-end the generator
or place it on its side. Fuel or oil can leak
and damage to the generator may occur.