2

PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1.

3/8 in. socket with ratchet.

2.

Channel-lock adjustable pliers.

3.

Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded 15 amp. branch

circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single phase, 60 Hz,

Alternating Current.

OUTLET RECEPTACLE

 - Properly grounded 3-prong receptacle to be

located so the power supply cord is accessible when the washer is in
an installed position.

GROUNDING REQUIREMENTS

  I

mproper connection of the equipment grounding

conductor can result in a risk of electrical shock. Check with a licensed
electrician if you are in doubt as to whether the appliance is properly
grounded.
1.

The washer 

MUST

 be grounded. In the event of a malfunction or

breakdown, grounding will reduce the risk of electrical shock by
a path of least resistance for electrical current.

2.

Since your washer is equipped with a power supply cord having
an equipment-grounding conductor and a grounding plug, the
plug 

MUST

 be plugged into an appropriate, copper wired

receptacle that is properly installed and grounded in accordance
with all local codes and ordinances or in the absence of local
codes, with the NationalElectricalCodes,
ANSI/NFPA 70 (latest edition). If in
doubt, call a licensed electrician.

DO NOT

 cut off or alter the

grounding prong on the power
supply cord. In situations where a
two-slot receptacle is present, it is
the owner’s responsi-
bility to have a licensed electrician

        replace it with a 

properly grounded

 three prong grounding

        type receptacle.
3.

For added personal safety, connect a separate ground wire (No.
18 minimum) from a top panel hinge screw on the rear of the
washer to a grounded cold water pipe. 

DO NOT

 ground to a gas

supply pipe or hot water pipe.

4.

Grounded cold water pipe 

MUST

 have metal continuity to electrical

ground and 

MUST

 register no more than 25 ohms resistance. It

MUST

 not be interrupted by plastic, rubber, or other electrical

insulating connectors such as hoses, fittings, washers, gaskets
(including water meter or pump). Any electrically insulated
connector should be jumped with a length of No. 4 copper wire
securely clamped to bare metal at both ends with a UL approved
ground clamp.

5.

If a grounded water pipe is not available, a ground rod

 MUST

 be

used and register no more than 25 ohms resistance when in the
ground. Drive the rod into the ground outside the dwelling and
connect a grounding wire (12 AWG or heavier) between the
grounding screw and the grounding rod. It may take more than
one ground rod to not exceed 25 ohms resistance to ground.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within 42 inches (107

cm) of your washer’s water inlet. The faucets 

MUST

 be 3/4 inch (1.9

cm) garden hose type so inlet hoses can be connected.  Water pressure

MUST

 be between 10 and 120 pounds per square inch (maximum

unbalance pressure, hot vs. cold, 10 psi.) Your water department can
advise you of your water pressure. The hot water temperature should
be about 140 degrees F (60 degrees C).

LOCATION OF YOUR WASHER

DO NOT INSTALL YOUR WASHER:

1.

In an area exposed to dripping water or outside weather
conditions. The ambient temperature should never be below 60
degrees F (15.6 degrees C) for proper washer operation.

2.

In an area where it will come in contact with curtains or drapes.

3.

In an area (garage or garage-type building) where gasoline of
other flammables are kept or stored (including automobiles).

4.

On carpet. Floor 

MUST BE SOLID

 with a maximum slope of 1 in.

(2.54 cm). To ensure vibration or movement does not occur,

REINFORCEMENT

 of the floor may be necessary.

IMPORTANT   MINIMUM INSTALLATION CLEARANCES

When installed in alcove:

Sides = 0" (0 cm),

Rear = 0" (0 cm), Top = 20" (50.8 cm).
When installed in closet:

Sides = 0" (0 cm),

Rear = 0" (0 cm), Top = 20" (50.8 cm), Front = 1"(2.54 cm).
Closet door ventilation openings required:  2 louvers each 60 square
inches (387 cm

2

) — 3 inches (7.6 cm) from bottom and top of door.

UNPACKING

1.

Using the four shipping carton corner posts (two on each side),
carefully lay the washer on its left side and remove foam shipping
base.

2.

Using a ratchet with 3/8" socket, remove the mechanism shipping
bolt and plastic spacer block from the center of the base.

3.

Return the washer to an upright position.

4.

Remove the tape holding the lid shut and open the lid.

5.

Remove the foam tub blocking pad.

6.

Remove the inlet hoses (some models have inlet hoses already
attached to the water valve) and enclosure package from the tub.

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gallons (64.3 L) per minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.

3.

The standpipe height above the floor should be:

Minimum  height:

33 in. (61 cm)

Maximum  height:

96 in. (244 cm)

96" Max.
(244 cm)

33" Min.
(61 cm)

NOTE:  

For installations requiring a longer drain hose, have a

qualified technician install a longer drain hose according to your
model number. For drain systems in the floor, install a syphon
break kit, P/N 5377678100. Both parts are available from an
authorized parts distributor.

ROUGH-IN DIMENSIONS

LID OPEN 90°

FRONT VIEW

SIDE VIEW

DRAIN
O U T L E T

DRAIN
O U T L E T
( R E A R )

WAT E R
I N L E T S
( R E A R )

27"

27"

3-3/4"

(129.54

cm)

(9.53 cm)

(68.58 cm)

(68.58 cm)

(74.77 cm)

29-7/16" (111.76

 cm)

44"

51"

11-7/16"

(29.05 cm)