4-64
Example:
Acceleration / deceleration timing when 05-00 is set to 1. In this example the following parameters are
set:
00-02=
【
1
】
(External Terminal Operation
)
00-04=
【
1
】
(Operation Mode: Run/Stop-Forward/Reverse).
03-00=
【
0
】
(Terminal S1: Run /Stop)
03-01=
【
1
】
(Terminal S2: Reversal /Stop)
03-02=
【
2
】
(Terminal S3: Preset Speed 1)
03-03=
【
3
】
(Terminal S4: Preset Speed 2)
03-03=
【
4
】
(Terminal S5: Preset Speed 3)
If the run command is cycled on and off, acceleration and deceleration time (a ~ f) is calculated based on the
active speed command as follows:
Terminal S1
Terminal S2
Terminal S3
Terminal S4
Run
Run
Run
Stop
Stop
Stop
Off
Off
Off
Off
On
On
a
b
c
d
e
f
Preset Spe
ed
0
Prese
t Spe
ed
1
Prese
t Spe
ed
2
05-01
05-02
05-03
T
Hz
in sec.
(05-17) x (05-01)
(05-18) x (05-01)
(05-19) x (05-02)
(01-02)
(01-02)
(01-02)
a =
b =
c =
(05-20) x (05-02)
(05-21) x (05-02)
(05-22) x (05-03)
(01-02)
(01-02)
(01-02)
d =
e =
f =
in sec.
Downloaded from Dealers Industrial Equipment -- Visit