18 | Westinghouse Outdoor Power Equipment, LLC
OPERATION
FUEL SELECTOR SWITCH
Position the fuel selector switch on the front control panel
to the desired fuel choice.
Push the fuel selector switch fully upward for gasoline
operation.
Push the fuel selector switch fully downward for propane
operation.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated
running watts (6000 watts) during the first five hours of
operation.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
LOW IDLE
NOTICE
Always start the generator with Low Idle OFF. Allow the
engine speed to stabilize before switching Low Idle ON.
NOTICE
Frequency output of the generator is dependent on
engine speed. DO NOT use Low Idle when powering
sensitive electronics or large surge loads, such as an
air conditioner, electric pump, refrigerator, or when
connected to a home transfer switch.
Low Idle minimizes fuel consumption, noise, and engine
wear by lowering the engine RPM to idle (2400 RPM) when
electrical loads have been turned off and automatically
returns to rated speed when loads are turned back on.
Turn Low Idle ON when powering intermittent, non-
electronic loads, such as power tools at a construction site.
BEFORE STARTING THE GENERATOR
Verify that:
• The generator is placed in an safe, appropriate location.
•
The generator is on a dry, flat, and level surface.
•
The engine is filled with oil.
• All loads are disconnected.
Fire and explosion hazard. DO NOT move or tip the
generator during operation.
STARTING THE ENGINE: GASOLINE
During Push-Button or Remote Start the engine will
automatically set the choke and begin the start sequence.
If the engine fails to start, the generator will attempt to
start the engine two more times. The battery switch can be
turned off at any time during the automatic start sequence
to abort the engine start attempt.
If the cranking speed drops after each unsuccessful
attempt, then the battery may not be adequately charged.
See BATTERY MAINTENANCE section
.
1.
Verify that fuel is in the gas tank.
2.
Turn the fuel selector switch to gasoline operation.
3.
Turn the fuel tank valve to the ON position.
4.
Push the battery switch to the ON position.
5.
Choose the starting method:
a. Remote Start:
Push and hold the START button on
the remote start key fob for one second.
b. Push-Button Start:
Push and hold the engine
START/STOP button for two seconds.
Summary of Contents for WGen12000DF
Page 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY SAFETY LABELS AND DECALS...
Page 9: ...Westinghouse Outdoor Power Equipment LLC 9 COMPONENTS COMPONENTS GENERATOR COMPONENTS...
Page 33: ...Westinghouse Outdoor Power Equipment LLC 33 EXPLODED VIEW GENERATOR EXPLODED VIEW...
Page 36: ...36 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS...