background image

Westinghouse Outdoor Power Equipment, LLC | 17

EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly 

into the home increase the risk of carbon monoxide 

poisoning through any openings. If an extension cord 

running directly into your home is used to power indoor 

items, there is a risk of carbon monoxide poisoning to 

people inside the home. 

ALWAYS

 use battery-powered 

carbon monoxide detector (s) that meet current UL 2034 

safety standards when running the generator. Regularly 

check the detector (s) battery.

Asphyxiation hazard. When operating the generator with 

extension cords, make sure the generator is located in 

an open, outdoor area, far away from occupied spaces 

with exhaust pointed away.

Fire and electrocution hazard. 

NEVER

 use worn or 

damaged extension cords. Damaged or overloaded 

extension cords could overheat, arc, and burn resulting 

in death or serious injury. 

Before connecting an AC appliance or power cord to the 

generator:

•  Use grounded 3-prong extension cords, tools, and 

appliances, or double-insulated tools and appliances. 

•  Make sure the tool or appliance is in good working 

order. Faulty appliances or power cords can create a 

potential for electric shock. 

•  Make sure the electrical rating of the tool or appliance 

does not exceed the rated power of the generator or the 

receptacle being used. 

EXTENSION CORD SIZING

Only use grounded 3-prong extension cords marked for 

outdoor use that are rated for the electrical load. 

TRANSPORTING

Weight hazard. 

ALWAYS

 have assistance when lifting 

the generator. 

•  Allow the generator to cool a minimum of 30 minutes 

before transporting.   

•  Replace all protective covers on the generator control 

panel. 

• 

Only use the generator’s fixed frame to lift the unit or 

attach any load restraints such as ropes or tie-down 

straps. 

DO NOT

 attempt to lift or secure the generator 

by holding onto any of its other components.

•  Keep the unit level during transport to minimize the 

possibility of fuel leakage or, if possible, drain the fuel 

or run the engine until the fuel tank is empty before 

transport.

OPERATION

Summary of Contents for WGen5300c

Page 1: ...MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen5300c Portable Generator Gasoline 5300 Running Watts 6600 Peak...

Page 2: ...is manual can result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMERS 2 ALL RIGHTS RESERVED 2 SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4...

Page 3: ...to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to temperatures outside of this range during storage i...

Page 4: ...could result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generat...

Page 5: ...properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws a...

Page 6: ...en filling the generator with gasoline DO NOT allow the generator s gas tank to overflow when filling Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the gen...

Page 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY LABELS SAFETY...

Page 8: ...l battery powered carbon monoxide alarm s in your home Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was imp...

Page 9: ...he NEMA 5 20R receptacles to 20 Amps 10 30 Amp AC Circuit Breaker Circuit breaker limits the current that can be delivered through the TT 30R receptacle to 30 Amps 11 Ground Terminal The ground termin...

Page 10: ...R COMPONENTS Oil drain bolt Oil dipstick filler neck Fuel cap Fuel gauge Muffler spark arrestor Carbon canister Carburetor Alternator cover Control panel Recoil Starter Air filter Fuel tank valve Spar...

Page 11: ...y Mounting foot 2 Flange bolt M8 4 Wheel 2 Axle pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service team at service wpowereq com or call 1 855 944 3571 INSTALL FEET AND WHEELS NOT...

Page 12: ...rd NEVER use a gasoline container gasoline tank or any other fuel item that is broken cut torn or damaged Fire and explosion hazard DO NOT overfill fuel tank Fill only to the red fill ring located in...

Page 13: ...proved gasoline container Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination 4 Slowly add the recommended fuel DO NOT overfill Fill only to...

Page 14: ...ed area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning the generator GRO...

Page 15: ...n Note If cold starting move the choke lever to the ON position 5 Choose the starting method a Push Button Start Push and hold the engine START STOP switch for two seconds b Recoil Start Manually clos...

Page 16: ...s RV Air Conditioner 11 000 BTU 1010 1600 TV Tube Type 300 0 RV Refrigerator 180 600 Radio 200 0 Light 75 Watts 300 0 Coffee Maker 600 0 Totals 2590 1600 Total Running Watts 2590 Highest Starting Watt...

Page 17: ...ord to the generator Use grounded 3 prong extension cords tools and appliances or double insulated tools and appliances Make sure the tool or appliance is in good working order Faulty appliances or po...

Page 18: ...ace air filter if it cannot be adequately cleaned 3 Recommend service to be performed by authorized Westinghouse service dealer MAINTENANCE REMINDERS Maintenance reminder codes will be shown on the Da...

Page 19: ...marks on the dipstick Safe Operating Range L H 5 If low add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick DO NOT overfill If over the H...

Page 20: ...024 0 032 in 0 60 0 80 mm Insulator Side Electrode 7 Carefully install the spark plug finger tight then tighten as additional 3 8 to 1 2 turn with the spark plug wrench 8 Attach the spark plug boot S...

Page 21: ...ilizer significantly increases the storage life of gasoline Full time use of fuel stabilizer is recommended Follow the manufacturer s instructions for use STORAGE TIME RECOMMENDED PROCEDURE Less than...

Page 22: ...OFF position 3 Remove the sediment cup from the fuel valve Remove the o ring and screen Fuel valve Screen O ring Cup 4 Wash the sediment cup o ring and screen in a nonflammable solvent Dry thoroughly...

Page 23: ...ault occurred Relocate generator Contact Westinghouse customer service toll free at 1 855 944 3571 Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Di...

Page 24: ...24 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS AND PARTS LIST ENGINE EXPLODED VIEW EXPLODED VIEWS...

Page 25: ...SPARK PLUG 9 CYLINDER HEAD COVER ASSEMBLY 9 1 91329 BOLT M6 16 NO PART DESCRIPTION 9 2 96225 CYLINDER HEAD COVER GASKET 9 3 401102 CYLINDER HEAD INTERNAL COVER 9 4 96226 INTERNAL COVER GASKET 9 5 4011...

Page 26: ...3 FLYWHEEL 15 3 404601 IMPELLER 15 4 90003 NUT M6 16 RECOIL STARTER ASSEMBLY 16 1 91325 BOLT M6 16 16 2 404707 221A STARTER ASSEMBLY 16 2 1 5943 PULL 16 2 2 5942 221 START PULLER 16 3 260801 CABLE CLI...

Page 27: ...Westinghouse Outdoor Power Equipment LLC 27 GENERATOR EXPLODED VIEW EXPLODED VIEWS...

Page 28: ...ANK CONNECTING PIPE 6 7 94423 FUEL LINE CLAMP 7 CONTROL PANEL ASSEMBLY 7 1 91327 BOLT M6X12 7 2 714385 CONTROL PANEL 7 2 1 536002 SWITCH NO PART DESCRIPTION 7 2 2 6691 IGNITION SWITCH 7 2 3 6393 INDIC...

Page 29: ...11 10 533302 221 ALTERNATOR TAIL COVER 11 11 91323 BOLT M5X16 11 12 91513 BOLT M5X175 11 13 90009 NUT M5 11 14 532303 052 TAIL BRACKET FIXING PLATE 11 15 94204 SPRING WASHER 12 CO MODULE ASSEMBLY 12...

Page 30: ...30 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...

Reviews: