Westinghouse Outdoor Power Equipment, LLC | 15
VOLTAGE SELECTOR SWITCH
The 120V/240V selector switch gives the user the ability to
double the amperage in the generator for more demanding
applications. The voltage selector switches the dual 120V
AC windings of the generator to produce 120V or 240V.
If a 240V appliance is connected to the 4-prong L14-30R
receptacle, the switch must be in the “240V” position. The
120V only outlets will not output power when the Voltage
Selector is in the 240V position.
Only change the Voltage Selector Switch with the
generator OFF.
DO NOT
switch the voltage while the
generator is running or powering appliances.
BREAK-IN PERIOD
For proper break-in,
DO NOT
exceed 50% of the rated
running watts (2650 watts) during the first five hours of
operation.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Verify that:
• The generator is placed in a safe, appropriate location.
•
The generator is on a dry, flat, and level surface.
•
The engine is filled with oil.
• All loads are disconnected.
Fire and explosion hazard.
DO NOT
move or tip the
generator during operation.
STARTING THE ENGINE
1.
Verify that fuel is in the gas tank.
2.
Turn the fuel selector switch on the control panel to
gasoline operation.
3.
Turn the fuel tank valve to the ON position.
Note:
If cold starting, move the choke lever to the ON
position.
4.
Push the Run/Stop switch to the Run position.
5.
Firmly grasp and pull the recoil handle slowly until you
feel increased resistance, then pull rapidly.
6.
After starting, allow the engine to run for several seconds
then move the Choke lever to the fully OFF position. .
STOPPING THE ENGINE
1.
Turn off and unplug all connected electrical loads.
IMPORTANT: NEVER
start or stop the generator with
electrical devices connected.
2.
Let the generator run with no load for several minutes to
stabilize internal temperatures of the engine.
3.
Push the Battery switch to the OFF position.
Note:
Alternately, if the generator is used infrequently, turn
the fuel tank valve to the OFF position to limit the
residual fuel remaining in the carburetor float bowl.
The engine will stop when fuel in the carburetor and
fuel line is exhausted.
OPERATION