DO NOT RETURN THIS PRODUCT TO THE STORE 

If you have questions or need assistance, please call customer 

service at 855-944-3571.

W

Gen

5300

DFc

 

Dual Fuel Portable Generator 

Gasoline: 5300 Running Watts | 6600 Peak Watts 

Propane: 4800 Running Watts | 5800 Peak Watts

Summary of Contents for WGEN5300DFC

Page 1: ...ODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen5300DFc Dual Fuel Portable Generator Gasoline 5300 Running Watts 6600 Peak Watts Propane 48...

Page 2: ...CONTENTS DISCLAIMERS 2 ALL RIGHTS RESERVED 2 INTRODUCTION SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4 SAFETY INSTRUCTIONS 5 SAFETY LABELS 8 SAFETY LABELS 9 CO SENSOR 10 ACTION LABEL...

Page 3: ...ntinuous operation at ambient temperatures up to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to tempe...

Page 4: ...esult in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generator pers...

Page 5: ...properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws a...

Page 6: ...A transfer switch must be installed by a licensed electrician approved by the authority having jurisdiction The installation must comply with all applicable laws and electrical codes FUEL SAFETY Stor...

Page 7: ...not used the regulator that is attached to the fuel tank The pressure as measured at the regulator mounted to the generator must be 7 to 14 of water column A certified plumber must ensure that the pr...

Page 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY LABELS SAFETY...

Page 9: ...Westinghouse Outdoor Power Equipment LLC 9 SAFETY SAFETY LABELS...

Page 10: ...attery powered carbon monoxide alarm s in your home WARNING Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator wa...

Page 11: ...5 20R Receptacles Receptacles can supply a maximum of 20 Amps 9 20 Amp AC Circuit Breaker Circuit breaker limits the current that can be delivered through the NEMA 5 20R receptacles to 20 Amps 10 30...

Page 12: ...NERATOR COMPONENTS Oil drain bolt Oil dipstick filler neck Fuel cap Fuel gauge Muffler spark arrestor Carbon canister Carburetor Alternator cover Control panel Recoil Starter Air filter Fuel tank valv...

Page 13: ...OTICE THIS GENERATOR HAS BEEN SHIPPED WITHOUT OIL DO NOT attempt to crank or start engine before it has been properly serviced with recommended oil Failure to add engine oil before starting will resul...

Page 14: ...e fuel system Follow the manufacturer s instructions for use ALWAYS mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator Run the generat...

Page 15: ...ane hose connector to the generator with a 19 mm or adjustable wrench DO NOT over tighten Torque 5 10 lb ft 6 Remove the safety plug or cap from the propane tank valve and attach the other end of the...

Page 16: ...yxiation hazard Place the generator in a well ventilated area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wi...

Page 17: ...fuel choice Turn the fuel selector switch fully upward for gasoline operation Turn the fuel selector switch fully downward for propane operation BREAK IN PERIOD For proper break in DO NOT exceed 50 o...

Page 18: ...to the ON position 2 Turn the fuel selector switch to gasoline operation 3 Turn the propane tank valve to the fully closed position Note When switching to propane operation the engine may run rough fo...

Page 19: ...Total Starting Watts Needed 4190 Wattages listed are approximate Verify actual wattage POWER MANAGEMENT To prolong the life of the generator and attached devices use care when adding electrical loads...

Page 20: ...the receptacle being used EXTENSION CORD SIZING Only use grounded 3 prong extension cords marked for outdoor use that are rated for the electrical load TRANSPORTING Weight hazard ALWAYS have assistan...

Page 21: ...ons Replace air filter if it cannot be adequately cleaned 3 Recommend service to be performed by authorized Westinghouse service dealer MAINTENANCE REMINDERS Maintenance reminder codes will be shown o...

Page 22: ...ag clean around the oil dipstick 3 Remove the oil dipstick and wipe the dipstick clean 4 Insert the dipstick into the oil filler neck without screwing it in Remove the dipstick and verify that the oil...

Page 23: ...spark plug Replace if electrodes are pitted burned or the insulator is cracked Only use a recommended replacement plug 6 Measure the spark plug electrode gap with a wire type feeler gauge If necessar...

Page 24: ...The use of fuel stabilizer significantly increases the storage life of gasoline Full time use of fuel stabilizer is recommended Follow the manufacturer s instructions for use STORAGE TIME RECOMMENDED...

Page 25: ...osition will help prevent internal corrosion Return the recoil handle gently 8 Reinstall the spark plug Leave the spark plug boot disconnected to prevent accidental starting VALVE CLEARANCE NOTICE Che...

Page 26: ...lter Bad fuel generator stored without treating or draining gasoline or refueled with bad gasoline Drain the fuel tank Refuel with fresh gasoline Fuel system malfunction fuel pump failure ignition mal...

Page 27: ...rmal immediately discontinue use and have the propane regulator inspected by a qualified technician Residual fuel from the carburetor dispersing after operation Normal no correction is needed Poor per...

Page 28: ...28 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS EXPLODED VIEWS AND PARTS LIST ENGINE EXPLODED VIEW...

Page 29: ...ASKET 9 3 401102 CYLINDER HEAD INTERNAL COVER NO PART DESCRIPTION 9 4 96226 INTERNAL COVER GASKET 9 5 401101 CYLINDER HEAD COVER 9 6 92036 SCREW 9 7 95603 BREATHER TUBE 9 8 94435 BREATHER TUBE CLIP 10...

Page 30: ...3 404601 IMPELLER 15 4 90003 NUT 16 50090067 RECOIL STARTER ASSEMBLY 16 1 91325 BOLT 16 2 404707 221A RECOIL STARTER ASSEMBLY 16 2 1 5943 RECOIL HANDLE 16 2 2 5942 221 RECOIL COVER 16 3 260801 Q SHAP...

Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 EXPLODED VIEWS GENERATOR EXPLODED VIEW...

Page 32: ...FILTER CONNECTING PIPE 6 2 91327 BOLT M6 6 3 94402 FUEL LINE CLAMP 6 4 94408 FUEL LINE CLAMP NO PART DESCRIPTION 6 5 543601L CARBON CANISTER ASSEMBLY 6 6 95020 CARBON CANISTER AND FUEL TANK CONNECTING...

Page 33: ...2 221 ALTERNATOR TAIL COVER 10 9 91323 BOLT M5 10 10 91513 BOLT M5 10 11 90009 NUT M5 10 12 532303 052 TAIL BRACKET FIXING PLATE 10 13 94204 SPRING WASHER 11 CO MODULE ASSEMBLY 11 1 599064 CO MODULE 1...

Page 34: ...34 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...