Westinghouse Outdoor Power Equipment, LLC | 17
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 2,000 ft. (762 m). Operation without this
adjustment will cause decreased performance, increased
fuel consumption, and increased emissions.
NOTICE
DO NOT
operate the generator at altitudes below 2,000
ft. (762 m) with the high altitude kit installed. Engine
damage may occur.
Note:
You must purchase both the Dual Fuel Regulator
and Carburetor Kit for proper high altitude operation.
High Altitude Carburetor Kit: Part# 518965
High Altitude DF Regulator: Part# 518516
Only change the Voltage Selector Switch with the
generator OFF.
DO NOT
switch the voltage while the
generator is running or powering appliances.
FUEL SELECTOR SWITCH
Position the fuel selector switch on the front control panel
to the desired fuel choice.
Turn the fuel selector switch fully upward for gasoline
operation.
Turn the fuel selector switch fully downward for propane
operation.
BREAK-IN PERIOD
For proper break-in,
DO NOT
exceed 50% of the rated
running watts (2650 watts) during the first five hours
of operation.Vary the load occasionally to allow stator
windings to heat and cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Verify that:
• The generator is placed in a safe, appropriate location.
•
The generator is on a dry, flat, and level surface.
•
The engine is filled with oil.
• All loads are disconnected.
Fire and explosion hazard.
DO NOT
move or tip the
generator during operation.
STARTING THE ENGINE: GASOLINE
1.
Verify that fuel is in the gas tank.
2.
Turn the fuel selector switch on the control panel to
gasoline operation.
3.
Turn the fuel tank valve to the ON position.
ON
OFF
Note:
If cold starting, move the choke lever to the ON
position.
4.
Push the Run/Stop switch to the Run position.
5.
Firmly grasp and pull the recoil handle slowly until you
feel increased resistance, then pull rapidly.
6.
After starting, allow the engine to run for several seconds
then move the Choke lever to the fully OFF position.
OPERATION
Summary of Contents for WGEN5300DFC
Page 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY LABELS SAFETY...
Page 9: ...Westinghouse Outdoor Power Equipment LLC 9 SAFETY SAFETY LABELS...
Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 EXPLODED VIEWS GENERATOR EXPLODED VIEW...
Page 34: ...34 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...