TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTION
Propane fuel smell
Fuel regulator or fuel hose and fittings not securely
sealed.
Using a soap solution check each connection and tighten as
needed.
Propane fuel regulator vent active.
The propane fuel regulator is equipped with a vent that will
allow a small amount of propane fuel vapor to escape from
the regulator when the propane tank valve is opened. This can
be normal providing the venting of the propane is brief. If you
suspect that this is abnormal, immediately discontinue use and
have the propane regulator inspected by a qualified technician.
Residual fuel from the carburetor dispersing after
operation.
Normal, no correction is needed.
Poor performance
or engine stalling on
Propane
Propane fuel line kinked or crushed.
Inspect propane fuel line and remove kinks or other
obstructions.
Fuel selector valve not properly positioned.
Rotate the fuel valve fully until the pointer is directly in line with
the desired fuel.
Gasoline not purged from the carburetor before
switching to propane.
Close the propane fuel tank valve. Move the fuel selector
switch to gas. Start the engine and allow the engine to run
until the gasoline has been consumed in the carburetor. Begin
propane start up procedure.
Summary of Contents for WGEN5300DFC
Page 8: ...8 Westinghouse Outdoor Power Equipment LLC SAFETY LABELS SAFETY...
Page 9: ...Westinghouse Outdoor Power Equipment LLC 9 SAFETY SAFETY LABELS...
Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 EXPLODED VIEWS GENERATOR EXPLODED VIEW...
Page 34: ...34 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...