background image

14 | Westinghouse Outdoor Power Equipment, LLC

 

OPERATION

OPERATION

GENERATOR LOCATION

Read and understand all safety information before starting 

the generator. 

NEVER

 operate the generator inside any building, including 

garages, basements, crawlspaces, sheds, enclosure, or 

compartment, including the generator compartment of a 

recreational vehicle.  

Electrocution hazard. 

NEVER

 use the generator in 

a location that is wet or damp. 

NEVER

 expose the 

generator to rain, snow, water spray, or standing water 

while in use. Protect the generator from all hazardous 

weather conditions. Moisture or ice can cause a short 

circuit or other malfunction in the electrical circuit. Using 

a generator or electrical appliance in wet conditions, 

such as rain or snow, or near a pool or sprinkler system, 

or when your hands are wet, could result in electrocution

Fire hazard. Only operate the generator on a solid, level 

surface. Operating the generator on a surface with loose 

material such as sand or grass clippings can cause debris 

to be ingested by the generator that could block cooling 

vents or the air intake system. Allow the generator to 

cool for 30 minutes before transport or storage.

The generator should be on a flat, level surface at all times 

(Even while not in operation). The generator must have 

at least 5 ft. (1.5 m) of clearance from all combustible 

material. 

DO NOT

 operate the generator in the back of a SUV, 

camper, trailer, truck bed (regular, flat, or otherwise), under 

stairs, next to walls or buildings, or in any other location 

that will not allow for adequate cooling of the generator 

and/or  the  muffler. 

DO NOT

 contain generators during 

operation.

Asphyxiation hazard. Place the generator in a well-

ventilated area. 

DO NOT

 place the generator near vents 

or intakes where exhaust fumes could be drawn into 

occupied  or  confined  spaces.  Carefully  consider  wind 

and air currents when positioning the generator.

GROUNDING

Shock hazard. Failure to properly ground the generator 

can result in electric shock.

NOTICE

Only use grounded 3-prong extension cords, tools, and 

appliances, or double-insulated tools and appliances.

The  generator  neutral  is  floating.  The  generator  ground 

terminal is connected to the frame of the generator, the 

metal non-current-carrying parts of the generator, and 

the ground terminals of each receptacle. The generator 

(stator winding) is isolated from the frame and from the 

AC receptacle ground pin. Electrical devices that require 

a grounded receptacle pin connection may not function 

properly. 
If this generator will be used only with cord and plug 

equipment connected to the receptacles mounted on the 

generator, National Electric Code does not require that 

the unit be grounded. However, other methods of using 

the generator may require grounding to reduce the risk of 

shock or electrocution. 

Before  using  the  ground  terminal,  consult  a  qualified 

electrician, electrical inspector, or local agency having 

jurisdiction for local codes or ordinances that apply to the 

intended use of the generator. 

HIGH ALTITUDE OPERATION

Engine power is reduced the higher you operate above sea 

level. Output will be reduced approximately 3.5% for every 

1000 feet of increased altitude from sea level. 
High altitude adjustment is required for operation at 

altitudes over 2,000 ft. (762 m). Operation without this 

adjustment will cause decreased performance, increased 

fuel consumption, and increased emissions. 

NOTICE

DO NOT

 operate the generator at altitudes below 2,000 ft. 

(762 m) with the high altitude kit installed. Engine damage 

may occur.

High Altitude Carburetor Kit Part# 518965

Summary of Contents for WGen5300sc

Page 1: ...ANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen5300sc Portable Generator Gasoline 5300 Running Watts 6600 Peak...

Page 2: ...result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMERS 2 ALL RIGHTS RESERVED 2 SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4 SAFETY INSTR...

Page 3: ...emperatures up to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to temperatures outside of this range d...

Page 4: ...uld result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generator...

Page 5: ...codes Electrocution hazard NEVER use the generator in a location that is wet or damp NEVER expose the generator to rain snow water spray or standing water while in use Protect the generator from all h...

Page 6: ...he generator NEVER remove the fuel cap when the generator is running Shut off the engine and allow the unit to cool at least two minutes Remove the fuel cap slowly to release pressure keep fuel from e...

Page 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY LABELS SAFETY...

Page 8: ...l battery powered carbon monoxide alarm s in your home Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was imp...

Page 9: ...eptacles Receptacles can supply a maximum of 20 Amps 8 20 Amp AC Circuit Breaker Circuit breaker limits the current that can be delivered through the NEMA 5 20R receptacles to 20 Amps 9 30 Amp AC Circ...

Page 10: ...R COMPONENTS Oil drain bolt Oil dipstick filler neck Fuel cap Fuel gauge Muffler spark arrestor Carbon canister Carburetor Alternator cover Control panel Recoil Starter Air filter Fuel tank valve Spar...

Page 11: ...components Item Quantity Mounting foot 2 Flange bolt M8 4 Wheel 2 Axle pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service team at service wpowereq com or call 1 855 944 3571 INST...

Page 12: ...fuel screen filter Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard Fire and explosion hazard NEVER refuel the generator while the engine is running ALWAYS turn the e...

Page 13: ...e red maximum fill ring on the fuel screen filter visible in the filler neck 5 Install the fuel cap NOTICE Fuel can damage paint and plastic Use caution when filling the fuel tank Damage caused by spi...

Page 14: ...l ventilated area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning the gen...

Page 15: ...fuel selector switch on the control panel to gasoline operation 4 Turn the fuel tank valve to the ON position Note If cold starting move the choke lever to the ON position 5 Choose the starting metho...

Page 16: ...er ON GENERATOR CAPACITY NOTICE DO NOT overload the generator s capacity Exceeding the generator s wattage amperage capacity can damage the generator and or electrical devices connected to it Make sur...

Page 17: ...N CORDS Asphyxiation hazard Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is u...

Page 18: ...frame to lift the unit or attach any load restraints such as ropes or tie down straps DO NOT attempt to lift or secure the generator by holding onto any of its other components Keep the unit level dur...

Page 19: ...formed by authorized Westinghouse service dealer MAINTENANCE REMINDERS Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours The maintenance codes will be displayed...

Page 20: ...tally and recheck until the level is between the L and H marks on the dipstick DO NOT overfill If over the H mark on the dipstick drain the oil to reduce the oil level to the full mark 6 Replace the o...

Page 21: ...park plug wrench 8 Attach the spark plug boot SPARK ARRESTOR SERVICE Allow the muffler to cool completely before servicing the spark arrestor Check and clean the spark arrestor after every 100 hours o...

Page 22: ...evity NOTICE Gasoline stored for as little as 30 days can deteriorate causing gum varnish and corrosive buildup in fuel lines fuel passages and the engine This corrosive buildup restricts the flow of...

Page 23: ...Storing the engine in this position will help prevent internal corrosion Return the recoil handle gently 8 Reinstall the spark plug Leave the spark plug boot disconnected to prevent accidental startin...

Page 24: ...occurred Relocate generator Contact Westinghouse customer service toll free at 1 855 944 3571 Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty...

Page 25: ...Westinghouse Outdoor Power Equipment LLC 25 EXPLODED VIEWS AND PARTS LISTS ENGINE EXPLODED VIEW EXPLODED VIEWS...

Page 26: ...R HEAD COVER ASSEMBLY 9 1 91329 BOLT 9 2 96225 CYLINDER HEAD COVER GASKET NO PART DESCRIPTION 9 3 401102 CYLINDER HEAD INTERNAL COVER 9 4 96226 INTERNAL COVER GASKET 9 5 401101 CYLINDER HEAD COVER 9 6...

Page 27: ...OIL STARTER ASSEMBLY 16 1 91325 BOLT 16 2 404707 221A RECOIL STARTER 16 2 1 5943 RECOIL HANDLE 16 2 2 5942 221 RECOIL COVER 16 3 260801 CABLE CLIP 17 STARTER MOTOR ASSEMBLY 17 1 97459 STARTING MOTOR 1...

Page 28: ...28 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS GENERATOR EXPLODED VIEW...

Page 29: ...L TANK CONNECTING PIPE 6 7 94423 FUEL LINE CLAMP 7 PANEL ASSEMBLY 7 1 91327 BOLT M6 7 2 714386 PANEL 7 2 1 6022 ENGINE SWITCH 7 2 2 6041 TIME ACCUMULATOR NO PART DESCRIPTION 7 2 3 6434 22 BREAKER 7 2...

Page 30: ...NO PART DESCRIPTION 11 11 91323 BOLT M5 11 12 91513 BOLT M5 11 13 90009 NUT M5 11 14 532303 052 TAIL BRACKET FIXING PLATE 11 15 94204 SPRING WASHER 12 CO MODULE ASSEMBLY 12 1 599063 CO MODULE 12 2 922...

Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 SCHEMATICS SCHEMATICS SCHEMATICS...

Reviews: