background image

20 | Westinghouse Outdoor Power Equipment, LLC

 

MAINTENANCE

ENGINE OIL LEVEL CHECK

Avoid skin contact with engine oil. Wear protective 

clothing and equipment. Wash all exposed skin with 

soap and water.

NOTICE

ALWAYS

 use the specified engine oil. Failure to use the 

specified engine oil can cause accelerated wear and/or 

shorten the life of the engine. 

When using the generator under dirty, dusty conditions or 

in extremely hot weather, change the oil more frequently. 
Ambient air temperature will affect engine oil performance. 

Change the type of engine oil used based on weather 

conditions.

Check the engine oil level before each use or every 8 

hours of operation.

1. 

Place the generator on a level surface and allow the 

engine to cool for several minutes.

2. 

With a damp rag, clean around the oil dipstick.

3. 

Remove the oil dipstick and wipe the dipstick clean. 

4. 

Insert the dipstick into the oil filler neck without screwing 

it in. Remove the dipstick and verify that the oil level 

is within safe operating range between the low (L) and 

high (H) marks on the dipstick. 

5. 

If low, add recommended engine oil incrementally and 

recheck until the level is between the L and H marks on 

the dipstick. 

DO NOT

 overfill. If over the H mark on the 

dipstick, drain the oil to reduce the oil level to the full 

mark.

6. 

Replace the oil dipstick and hand-tighten.

ENGINE OIL CHANGE

When using the generator under dirty, dusty conditions or 

in extremely hot weather, change the oil more frequently. 

Change the oil while the engine is still warm from operation. 

1. 

Place the generator on a level surface and allow the 

engine to cool for several minutes.

2. 

With a damp rag, clean around the oil dipstick. Remove 

the dipstick and wipe clean. 

3. 

Place an oil pan (or suitable container) under the oil 

drain bolt.

4. 

Using a 10mm wrench, remove the oil drain bolt and 

allow the oil the to drain. 

5. 

Install the oil drain bolt and tighten securely. 

Note: 

A new oil drain plug crush washer is recommended 

at each oil change.

6. 

Slowly pour oil into the oil filler neck until oil the level 

is between the L and H marks on the dipstick. Stop 

frequently to check the oil level. 

DO NOT

 overfill. 

Maximum oil capacity: 0.74 Quart (0.7 Liter)
7. 

Install the oil dipstick and hand-tighten.

 

NOTICE

DO NOT

 pollute. Follow the guidelines of the EPA or other 

governmental agencies for proper disposal of hazardous 

materials. Consult local authorities or reclamation facility.

Summary of Contents for WGen5300sc

Page 1: ...ANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen5300sc Portable Generator Gasoline 5300 Running Watts 6600 Peak...

Page 2: ...result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMERS 2 ALL RIGHTS RESERVED 2 SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4 SAFETY INSTR...

Page 3: ...emperatures up to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to temperatures outside of this range d...

Page 4: ...uld result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generator...

Page 5: ...codes Electrocution hazard NEVER use the generator in a location that is wet or damp NEVER expose the generator to rain snow water spray or standing water while in use Protect the generator from all h...

Page 6: ...he generator NEVER remove the fuel cap when the generator is running Shut off the engine and allow the unit to cool at least two minutes Remove the fuel cap slowly to release pressure keep fuel from e...

Page 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY LABELS SAFETY...

Page 8: ...l battery powered carbon monoxide alarm s in your home Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was imp...

Page 9: ...eptacles Receptacles can supply a maximum of 20 Amps 8 20 Amp AC Circuit Breaker Circuit breaker limits the current that can be delivered through the NEMA 5 20R receptacles to 20 Amps 9 30 Amp AC Circ...

Page 10: ...R COMPONENTS Oil drain bolt Oil dipstick filler neck Fuel cap Fuel gauge Muffler spark arrestor Carbon canister Carburetor Alternator cover Control panel Recoil Starter Air filter Fuel tank valve Spar...

Page 11: ...components Item Quantity Mounting foot 2 Flange bolt M8 4 Wheel 2 Axle pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service team at service wpowereq com or call 1 855 944 3571 INST...

Page 12: ...fuel screen filter Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard Fire and explosion hazard NEVER refuel the generator while the engine is running ALWAYS turn the e...

Page 13: ...e red maximum fill ring on the fuel screen filter visible in the filler neck 5 Install the fuel cap NOTICE Fuel can damage paint and plastic Use caution when filling the fuel tank Damage caused by spi...

Page 14: ...l ventilated area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning the gen...

Page 15: ...fuel selector switch on the control panel to gasoline operation 4 Turn the fuel tank valve to the ON position Note If cold starting move the choke lever to the ON position 5 Choose the starting metho...

Page 16: ...er ON GENERATOR CAPACITY NOTICE DO NOT overload the generator s capacity Exceeding the generator s wattage amperage capacity can damage the generator and or electrical devices connected to it Make sur...

Page 17: ...N CORDS Asphyxiation hazard Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is u...

Page 18: ...frame to lift the unit or attach any load restraints such as ropes or tie down straps DO NOT attempt to lift or secure the generator by holding onto any of its other components Keep the unit level dur...

Page 19: ...formed by authorized Westinghouse service dealer MAINTENANCE REMINDERS Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours The maintenance codes will be displayed...

Page 20: ...tally and recheck until the level is between the L and H marks on the dipstick DO NOT overfill If over the H mark on the dipstick drain the oil to reduce the oil level to the full mark 6 Replace the o...

Page 21: ...park plug wrench 8 Attach the spark plug boot SPARK ARRESTOR SERVICE Allow the muffler to cool completely before servicing the spark arrestor Check and clean the spark arrestor after every 100 hours o...

Page 22: ...evity NOTICE Gasoline stored for as little as 30 days can deteriorate causing gum varnish and corrosive buildup in fuel lines fuel passages and the engine This corrosive buildup restricts the flow of...

Page 23: ...Storing the engine in this position will help prevent internal corrosion Return the recoil handle gently 8 Reinstall the spark plug Leave the spark plug boot disconnected to prevent accidental startin...

Page 24: ...occurred Relocate generator Contact Westinghouse customer service toll free at 1 855 944 3571 Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty...

Page 25: ...Westinghouse Outdoor Power Equipment LLC 25 EXPLODED VIEWS AND PARTS LISTS ENGINE EXPLODED VIEW EXPLODED VIEWS...

Page 26: ...R HEAD COVER ASSEMBLY 9 1 91329 BOLT 9 2 96225 CYLINDER HEAD COVER GASKET NO PART DESCRIPTION 9 3 401102 CYLINDER HEAD INTERNAL COVER 9 4 96226 INTERNAL COVER GASKET 9 5 401101 CYLINDER HEAD COVER 9 6...

Page 27: ...OIL STARTER ASSEMBLY 16 1 91325 BOLT 16 2 404707 221A RECOIL STARTER 16 2 1 5943 RECOIL HANDLE 16 2 2 5942 221 RECOIL COVER 16 3 260801 CABLE CLIP 17 STARTER MOTOR ASSEMBLY 17 1 97459 STARTING MOTOR 1...

Page 28: ...28 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS GENERATOR EXPLODED VIEW...

Page 29: ...L TANK CONNECTING PIPE 6 7 94423 FUEL LINE CLAMP 7 PANEL ASSEMBLY 7 1 91327 BOLT M6 7 2 714386 PANEL 7 2 1 6022 ENGINE SWITCH 7 2 2 6041 TIME ACCUMULATOR NO PART DESCRIPTION 7 2 3 6434 22 BREAKER 7 2...

Page 30: ...NO PART DESCRIPTION 11 11 91323 BOLT M5 11 12 91513 BOLT M5 11 13 90009 NUT M5 11 14 532303 052 TAIL BRACKET FIXING PLATE 11 15 94204 SPRING WASHER 12 CO MODULE ASSEMBLY 12 1 599063 CO MODULE 12 2 922...

Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 SCHEMATICS SCHEMATICS SCHEMATICS...

Reviews: