STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the first
time starting make sure to add oil (see
Adding Engine Oil
page 24
).
1.
Make sure nothing is plugged into power outlets.
2.
Verify the battery is installed and both battery
cables are attached to their corresponding polarity.
(See
Installing the Battery
on page 11)
3.
Make sure the circuit breakers are properly set (see
Figure 8 below).
Figure 8 - Breakers
1
240/120VMain Circuit Breaker Operating Position
2
240/120V Main Circuit Breaker Tripped Position
3
120V Circuit Breaker Operating Position
4
120V Circuit Breaker Tripped Position
4. Move the fuel shut off valve to the
ON
position (see
Figure 9 below).
ON
OFF
Figure 9 - Fuel Shut Off - ON
5. For cold starting move the choke lever to the
ON
position (see Figure 10 below). If warm starting move
choke to
OFF
position.
Figure 10 - Cold Start Choke Lever - ON
6.
Choose starting method:
a.
Electric Start:
Push and hold the engine control
switch in the
START
position until the engine
starts. Once the engine starts, release the engine
control switch; the switch will automatically move
into the
RUN
position (see Figure 11 below).
START
RUN
STOP
Figure 11 - Engine Control Switch - START
NOTICE
Failure to release the engine control switch once the engine
starts could result in damage to the generator.
Never push the engine control switch to the
START
position while the engine is running’ this could damage the
generator.
Note: If the engine fails to start after 5
seconds, release the engine control switch.
Let the generator sit idle for 15 seconds and
then repeat step 8. If the cranking speed
drops after each unsuccessful attempt, then
the battery may not be adequately charged.
Manually start the generator by following
steps below:
b.
Manual Start:
Make sure the engine control
switch is in the
RUN
position.
Firmly grasp
and pull the recoil handle slowly until you feel
increased resistance. At this point, apply a rapid
pull while pulling up and slightly away from the
generator.
START
RUN
STOP
Figure 12 - Cold Start Choke Lever - OFF
7.
After cold starting, as the engine starts and stabilizes,
gradually move the choke lever back to the
OFF
position (see Figure 13 below).
Figure 13 - Cold Start Choke Lever - OFF
8. Plug in electric devices.
OPERATION
Summary of Contents for WGen6000
Page 1: ...USER MANUAL WGen6000 Portable Generator 6000 Running Watts 7500 Peak Watts...
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 7 10 8 9 6 6 7 5 10 9...
Page 30: ...30 Westinghouse Portable Power WGEN6000 EXPLODED VIEW...
Page 34: ...34 Westinghouse Portable Power WGEN6000 SCHEMATIC WH7500v SCHEMATIC...
Page 36: ...36 Westinghouse Portable Power Version 08 10 18KD...