Westinghouse Portable Power | 29
WARNING
Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner’s manual and
understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can lead to voiding of the EPA
certification or product warranty, serious personal injury, property damage or even death.
TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
Engine is running, but no
electrical output
1. Circuit breakers are tripped.
1. Reset the circuit breakers and check for overload
condition.
2. The power cord’s plug connector is not fully
engaged in the generator’s outlet.
2. Verify plug connector is firmly engaged in the
generator’s outlet. If using the 240V outlet, make sure plug
connector is rotated 1/4 turn in the clockwise direction.
3. Faulty or defective power cord
3. Replace power cord.
4. Faulty or defective electrical appliance
4. Try connecting a known good appliance to verify the
generator is producing electrical power.
5. GFCI outlet is tripped
5. Press the reset button on the GFCI outlet.
6. If trying 1-5 above does not solve the
problem, the cause might be the generator has
a fault.
6. Take the generator to your nearest authorized service
dealer.
Engine will not start or
remain running while
trying to start.
1. Fuel shutoff valve is in the OFF position.
1. Move the fuel shut off valve to the ON position.
2. Generator is out of gasoline.
2. Add gasoline to the generator.
3. Fuel flow is obstructed.
3. Inspect and clean fuel delivery passages.
4. Unit is over choked.
4. Move the choke lever halfway between the ON and OFF
positions.
5. Starting battery may have insufficient charge
5. On electric start models only. Check battery output and
charge battery as necessary.
6. Dirty air filter
6. Check and clean the air filter.
7. Low oil level shut down switch is preventing
the unit from starting.
7. Check oil level and add oil if necessary.
8. Spark plug boot is not fully engaged with the
spark plug tip.
8. Firmly push down on the spark plug boot to ensure the
boot is fully engaged
9. Spark plug is faulty.
9. Remove and check the spark plug. Replace if faulty.
10. Dirty/plugged spark arrestor
10. Check and clean the spark arrestor.
11. Stale fuel
11. Drain fuel and replace with fresh fuel.
12. If trying 1-11 above does not solve the
problem, the cause might be the generator has
a fault.
12. Take the generator to your nearest authorized service
dealer.
Generator suddenly
stops running.
1. Generator is out of fuel.
1. Check fuel level. Add fuel if necessary.
2. The low oil shut down switch has stopped
the engine.
2. Check oil level and add oil if necessary.
3. Too much load
3. Restart the generator and reduce the load.
4. If trying 1-3 above does not solve the
problem,the cause might be a fault in the
generator.
4. Take the generator to your nearest authorized service
dealer.
Engine runs
erratic; does not hold a
steady RPM.
1. Choke was left in the
ON
position.
1. Move choke to the OFF position
2. Dirty air filter
2. Clean the air filter.
3. Applied loads maybe cycling on and off
3. As applied loads cycle, changes in engine speed may
occur; this is a normal condition.
4. If trying 1-3 above does not solve
the problem, the cause might be a
fault in the generator
4. Take the generator to your nearest authorized service
dealer.
Summary of Contents for WGen6000
Page 1: ...USER MANUAL WGen6000 Portable Generator 6000 Running Watts 7500 Peak Watts...
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 7 10 8 9 6 6 7 5 10 9...
Page 30: ...30 Westinghouse Portable Power WGEN6000 EXPLODED VIEW...
Page 34: ...34 Westinghouse Portable Power WGEN6000 SCHEMATIC WH7500v SCHEMATIC...
Page 36: ...36 Westinghouse Portable Power Version 08 10 18KD...