Westinghouse Outdoor Power Equipment, LLC | 21
MAINTENANCE
MAINTENANCE
WARNING
Accidental start-up. Disconnect the spark plug boot from
the spark plug and disconnect the battery quick-connect
plugs when performing maintenance on the generator.
MAINTENANCE SCHEDULE
Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
1
Clean air filter
2
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Fuel valve maintenance
Inspect/adjust valve clearance
3
After 300 Hours or Every Year
Replace spark plug
Replace air filter
1
Change oil every month when operating under heavy
load or in high temperatures.
2
Clean more often under dirty or dusty conditions.
Replace air filter if it cannot be adequately cleaned.
3
Recommend service to be performed by authorized
Westinghouse service dealer.
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
Maintenance Code Required Maintenance
P25
Change engine oil
P50
Change engine oil, clean air filter
P100
• Change engine oil
•
Clean air filter
• Fuel valve maintenance
• Inspect/adjust valve clearance
MAINTENANCE REPLACEMENT PARTS
Description
Part Number
Air filter
5205
Oil drain plug crush washer
94004
Spark arrestor
6866
Battery, 9.0 AH
511008
Spark plug
97108 (F7TC)
AIR FILTER MAINTENANCE
WARNING
Fire hazard.
NEVER
use gasoline or other flammable
solvents to clean the air filter. Use only household
detergent soap to clean the air filter.
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1.
Place the generator on a level surface and allow the
engine to cool for several minutes.
2.
Release the top and bottom clips then remove the air
filter cover.
3.
Remove the air filters. Use compressed air to clean the
coarse air filter.
Note:
The foam air filter element is oil soaked. Use an
appropriate cleaning container.
NOTICE
Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
4.
Remove the foam air filter and wash it by submerging
the element in a solution of household detergent soap
and warm water. Slowly squeeze the foam to thoroughly
clean.
Summary of Contents for WGen7500c
Page 9: ...Westinghouse Outdoor Power Equipment LLC 9 SAFETY LABELS AND DECALS SAFETY...
Page 11: ...Westinghouse Outdoor Power Equipment LLC 11 COMPONENTS GENERATOR COMPONENTS...
Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 EXPLODED VIEW B EXPLODED VIEWS...
Page 34: ...34 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...