Westinghouse Portable Power | 25
3. The reset button should pop out and there will
be no power from the outlets. If the reset button
does not pop out, the GFCI outlet is not working
correctly and must be repaired before the generator
can be operated.
4.
Press the reset button to restore power to the
outlet.
CLEANING THE GENERATOR
It is important to inspect and clean the generator before
every use.
Clean All Engine Air Inlet and Outlet Ports
– Make
sure all engine air inlet and outlet ports are clean of any
dirt and debris to ensure the engine does not run hot.
Clean All Engine Cooling Fins
– Use a damp rag and
a brush to loosen and remove all dirt on or around the
engine’s cooling fins.
Clean All Alternator Cooling Air Inlets and Exhaust
Ports
– Make sure the cooling air inlets and exhaust
ports of the alternator are free of any debris and ob-
structions. Use a vacuum cleaner to remove dirt and
debris stuck in the cooling air inlets and exhaust ports.
General Cleaning of the Generator
– Use a damp rag
to clean all remaining surfaces.
TESTING GFCI OUTLETS
1.
Start the generator and allow it to warm up.
2.
Press the test button on the GFCI outlet.
MAINTENANCE
Test Button
Reset Button
CHECKING AND ADJUSTING VALVE LASH
CAUTION
Checking and adjusting valve lash
must be done when the engine is cold.
1.
Remove the rocker arm cover and carefully remove
the gasket. If the gasket is torn or damaged, it must
be replaced.
2.
Remove the spark plug so the engine can be
rotated more easily.
3.
Rotate the engine to top dead center (TDC) of the
compression stroke. Looking through the spark
plug hole, the piston should be at the top.
4. Both the rocker arms should be loose at TDC on
the compression stroke. If they are not, rotate the
engine 360°.
5.
Insert a feeler gauge between the rocker arm and
the push rod and check for clearance (see Figure
23). See Table 2 for valve lash specifications
Figure 23
(1) Push Rod, (2) Feeler Gauge Area
(3) Rocker Arm, (4) Jam Nut, (5) Adjusting Nut
(Table 2) Standard Valve Lash
Intake Valve
Exhaust Valve
Valve Lash
0.0035 ± 0.0043 in
(0.09 ± 0.11 mm)
0.0043 ± 0.0051 in
(0.11 ± 0.13 mm)
Bolt Torque
8-12N.m
8-12N.m
6. If an adjustment is required, hold the adjusting nut
and loosen the jam nut.
1
2
3
4
5
Summary of Contents for WH10000
Page 1: ...USER MANUAL WH10000 Portable Generator 8000 Running Watts 10000 Peak Watts...
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 7 10 8 9 6 6 7 5 10 9...
Page 32: ...32 Westinghouse Portable Power WH10000 SCHEMATIC...
Page 33: ...Westinghouse Portable Power 33 Version 12 17 18KD...