TROUBLESHOOTING
PRObLEM
POTENTIAL CAUSE
SOLUTION
Engine is running, but
no 240-Volt AC output is
available.
1. If VFT meter display is blank,
generator may be faulty.
1. Take generator to an authorized Westinghouse
service dealer.
2. Main 240-Volt AC circuit
breaker and/or individual 240-
Volt AC outlet circuit breakers
(if equipped) are in the OFF
position.
2. Switch main 240-Volt AC circuit breaker and individual
240-Volt AC outlet circuit breakers (if equipped) to the
ON position.
3. RCD safety switch circuit
breaker (if equipped) is in the
OFF position.
3. Move RCD safety switch circuit breaker (if equipped)
to the ON position.
4. Connected electrical cord or
device plug is not properly
inserted into 240-Volt AC
outlet socket.
4. Check connected electrical cord or appliance plug is
fully inserted into the 240-Volt AC outlet socket.
5. Connected electrical cord or
device is faulty.
5. Connect known functioning device directly into
generator’s 240-Volt AC outlet socket to verify
electrical output.
6. If above possible causes
are checked and eliminated,
generator may be faulty.
6. Take generator to an authorized Westinghouse
service dealer.
Engine is running, but
no 12-Volt DC output is
available.
1. 12-Volt DC circuit breaker is
in the OFF position.
1. Switch 12-Volt DC circuit breaker to the ON position.
2. Connected electrical cord or
device plug is not properly
inserted into 12-Volt DC outlet
socket.
2. Check connected electrical cord or device plug is fully
inserted into the 12-Volt DC outlet socket.
3. Connected electrical cord or
device is faulty.
3. Connect known functioning device directly into
generator’s 12-Volt DC outlet socket to verify electrical
output.
4. If above possible causes
are checked and eliminated,
generator may be faulty.
4. Take generator to an authorized Westinghouse
service dealer.
Engine stops during
operation.
1. Generator is out of fuel.
1. Check fuel level and add fuel if necessary.
2. Fuel is contaminated with
water or other foreign
substance.
2. Drain fuel and refill with fresh fuel.
3. Low oil level.
3. Check oil level and add oil if necessary.
4. Overload or short circuit in the
240-Volt AC system.
4. Disconnect all electrical cords and devices from
generator and switch all AC circuit breakers OFF.
Re-start generator and then re-connect electrical
loads individually if possible. Check running and
starting power demands of total connected electrical
load versus generator’s rating.
5. If above possible causes
are checked and eliminated,
generator may be faulty.
5. Take generator to an authorized Westinghouse
service dealer.