CARE AND CLEANING

The following maintenance procedures must be routinely followed in order to
ensure proper, efficient operation of your Humidifier. 

IMPORTANT: The unit WILL NOT WORK CORRECTLY if it is not cleaned and

maintained properly. Proper cleaning is absolutely essential to avoid algae or
bacteria build-up.

When the unit is in use, daily and weekly maintenance is recommended to
prevent scale buildup and micro-organisms from growing on both the Wick
Filter and the Water Basin. This ensures that maximum efficiency will 
be achieved.

REPLACING THE WICK FILTER

Through normal use, waterborne minerals and sediment become trapped in the
Wick Filter turning the Filter brown in color, a sign that changing is needed. The
harder your water, the greater the amount of minerals in the water, and the more
often you will need to change your Wick Filter.  Regular Filter replacement is
necessary to ensure optimal Humidifier performance.

To replace the Wick Filter, follow the steps below.

1. Press the ON/OFF Button to turn the unit OFF and unplug the unit.

2. Use the Water Tank Handle (on the top of the Water Tank) to lift the Tank

straight up and out of the Water Tank Housing.

3. Press the Release Buttons on both side panels and lift the Main Body straight

up and off the Water Basin.

4. Discard the old Wick Filter and replace with a new 2-Piece Wick Filter. One

new Wick Filter will fit around the curved area; the other fits along the flat
back area of the Filter Holder.

5. Following the OPERATING INSTRUCTIONS outlined previously in this Owner’s

Manual, program your Cool Mist Humidifier to run for 30 minutes, allowing the
Humidifier to reach maximum output.

NOTE: The Cool Mist Humidifier uses Model WST7505 2-Piece Replacement 

Wick Filter. 

10

INTRODUCTION

Your Cool Mist Humidifier is designed to dispense a cool mist quietly and efficiently
while maintaining your preferred level of humidity. Enjoy continuous cool air misting
or program the Humidifier to run from 1 to 8 hours with automatic shut off. 

NOTE: The Cool Mist Humidifier holds 1.2 gallons of water and will run for 

12 hours of continuous operation before refilling is necessary. 

NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The

recommended humidity level is between 40% and 50%.

BEFORE USING FOR THE FIRST TIME

1. Be sure the Humidifier is switched to OFF and the unit is unplugged. 

2. Choose a suitable location for the Cool Mist Humidifier on a flat surface, with the

front of the Cool Mist Outlet at least 6 feet 6 inches from the nearest wall. DO
NOT place the Humidifier on a finished floor or near furniture, which can be
damaged by moisture or water. NEVER place the Humidifier in a closed room. 

3. Lift the Cool Mist Humidifier using the Carry Handle and place on a moisture-

resistance surface.

FILLING THE WATER TANK

1. Use the Water Tank Handle (on the top of the Water Tank) to lift the Tank straight

up and out of the Humidifier Housing. Turn the empty Tank upside down; unscrew
the Water Tank Lid by turning counter-clockwise, Remove the Lid. 

2. Fill Tank with cool, tap water or bottled distilled water.* 

*In areas where tap water is hard, it is recommended that distilled water be used.

CAUTION: The Water Tank is delicate and may crack if dropped or bumped. To ensure

proper performance of your Cool Mist Humidifier, use care when filling and
transporting the Water Tank.

WARNING: DO NOT fill with warm water as this may cause leaking. 

IMPORTANT: Check the inside of the Lid to make sure the Rubber Seal Ring is correctly

positioned before replacing the Lid. 

3. Make sure the Rubber Ring is in position, sitting flat in the groove on the inside

of the Lid. Twist the Lid clockwise and firmly lock onto the Tank. 

4. Firmly grasping the Water Tank Handle, re-insert into the Humidifier Housing

inside the Water Basin. The Tank will immediately begin to empty into the Water
Basin of the Humidifier.

NOTE: Replace the Water Tank so that the Water Tank Handle faces left.

5

Summary of Contents for WST7503

Page 1: ... Is Not Covered This warranty does not cover damage resulting from misuse accident commercial use improper service or any other damage caused by anything other than defects in material or workmanship during ordinary consumer use This warranty is invalid if the serial number has been altered or removed from the product This warranty is valid only in the United States and Canada LIMITATION ON DAMAGE...

Page 2: ...iance into a 120V AC electrical outlet 3 Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs near heat registers radiators stoves or heaters 4 DO NOT place Humidifier near heat sources such as stoves radiators and heaters DO locate your Humidifier on an inside wall near an electrical outlet The Humidifier should be at least 6 6 feet 2 m away from the wall fo...

Page 3: ...ause damage particularly to wall paper 15 The Humidifier should be unplugged when not in use 16 NEVER tilt move or attempt to empty while the Cool Mist Humidifier is operating Press the ON OFF Button to turn the unit OFF and unplug before removing the Water Tank and moving the unit 17 This Humidifier requires daily and weekly maintenance Refer to daily and weekly cleaning procedures Use only clean...

Page 4: ...on replace the Water Tank without the Lid Follow Storage Instructions outlined in this Owner s Manual 12 CONSUMER SAFETY INFORMATION NOTE This is an electrical appliance and requires attention when in use NOTE If moisture forms on the walls or windows of the room turn OFF the Humidifier The room already has plenty of humidity and additional moisture may cause damage NOTE DO NOT block air inlets or...

Page 5: ...oth or paper towel 6 If necessary replace the Wick Filter s following the instructions outlined in the REPLACING THE WICK FILTER section of this manual Replace the Wick Filter Holder into the recessed area of the Water Basin 7 Replace the Humidifier Main Housing Make sure it is properly fitted onto the Water Basin before operating 8 Refill the Water Tank with cool tap water Replace the Water Tank ...

Page 6: ... 10 INTRODUCTION Your Cool Mist Humidifier is designed to dispense a cool mist quietly and efficiently while maintaining your preferred level of humidity Enjoy continuous cool air misting or program the Humidifier to run from 1 to 8 hours with automatic shut off NOTE The Cool Mist Humidifier holds 1 2 gallons of water and will run for 12 hours of continuous operation before refilling is necessary ...

Page 7: ...previously preset humidity When the current humidity level is less than the preset humidity level a fine mist will moisten the air until the preset humidity level is reached The Humidifier will automatically cycle ON and OFF as it maintains the proper humidity level NOTE Make sure the front of the Cool Mist Outlet is at least 6 feet 6 inches from the nearest wall NOTE If the current room humidity ...

Page 8: ...S RUN and will continue to operate as long as the Water Tank has an adequate amount of water to run or until the Humidifier reaches the desired set humidity 8 7 ADJUSTING THE FAN SPEED NOTE The Cool Mist Humidifier has a 3 Speed Fan that can be easily adjusted to provide individual comfort 1 Plug the Cool Mist Humidifier into a 120V AC electrical outlet 2 The Display will show LOW FAN Each time th...

Page 9: ...S RUN and will continue to operate as long as the Water Tank has an adequate amount of water to run or until the Humidifier reaches the desired set humidity 8 7 ADJUSTING THE FAN SPEED NOTE The Cool Mist Humidifier has a 3 Speed Fan that can be easily adjusted to provide individual comfort 1 Plug the Cool Mist Humidifier into a 120V AC electrical outlet 2 The Display will show LOW FAN Each time th...

Page 10: ...previously preset humidity When the current humidity level is less than the preset humidity level a fine mist will moisten the air until the preset humidity level is reached The Humidifier will automatically cycle ON and OFF as it maintains the proper humidity level NOTE Make sure the front of the Cool Mist Outlet is at least 6 feet 6 inches from the nearest wall NOTE If the current room humidity ...

Page 11: ... 10 INTRODUCTION Your Cool Mist Humidifier is designed to dispense a cool mist quietly and efficiently while maintaining your preferred level of humidity Enjoy continuous cool air misting or program the Humidifier to run from 1 to 8 hours with automatic shut off NOTE The Cool Mist Humidifier holds 1 2 gallons of water and will run for 12 hours of continuous operation before refilling is necessary ...

Page 12: ...oth or paper towel 6 If necessary replace the Wick Filter s following the instructions outlined in the REPLACING THE WICK FILTER section of this manual Replace the Wick Filter Holder into the recessed area of the Water Basin 7 Replace the Humidifier Main Housing Make sure it is properly fitted onto the Water Basin before operating 8 Refill the Water Tank with cool tap water Replace the Water Tank ...

Page 13: ...on replace the Water Tank without the Lid Follow Storage Instructions outlined in this Owner s Manual 12 CONSUMER SAFETY INFORMATION NOTE This is an electrical appliance and requires attention when in use NOTE If moisture forms on the walls or windows of the room turn OFF the Humidifier The room already has plenty of humidity and additional moisture may cause damage NOTE DO NOT block air inlets or...

Page 14: ...ause damage particularly to wall paper 15 The Humidifier should be unplugged when not in use 16 NEVER tilt move or attempt to empty while the Cool Mist Humidifier is operating Press the ON OFF Button to turn the unit OFF and unplug before removing the Water Tank and moving the unit 17 This Humidifier requires daily and weekly maintenance Refer to daily and weekly cleaning procedures Use only clean...

Page 15: ...iance into a 120V AC electrical outlet 3 Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs near heat registers radiators stoves or heaters 4 DO NOT place Humidifier near heat sources such as stoves radiators and heaters DO locate your Humidifier on an inside wall near an electrical outlet The Humidifier should be at least 6 6 feet 2 m away from the wall fo...

Page 16: ... Is Not Covered This warranty does not cover damage resulting from misuse accident commercial use improper service or any other damage caused by anything other than defects in material or workmanship during ordinary consumer use This warranty is invalid if the serial number has been altered or removed from the product This warranty is valid only in the United States and Canada LIMITATION ON DAMAGE...

Reviews: