71
Appendix: Maintenance schedule
704 67 020 00 _ 111
OPERATING INSTRUCTIONS
GF Robimat XL / XM
Machine:
Robimat XL/ XM / EC
Housing
Resources
Spare part number
Action/Frequency
1 = clean
2 = test/ check
3 = lubricate
4 = replace/ exchange
OK
12 Months or
30,000
1)
24 Months or
60,000
1)
36 Months or
90000
1)
Is the machine standing safely, no
tilting, firmly secured?
2
2
2
Does the glass door close without
any resistance?
2
2
2
External housing
1
1
1
Coach bolts at top and bottom of
glass door
Special lubricant
e. g. Microlube GL 261
part no. 998 90 037 01
2+3
2+3
2+3
Locking hook
Special lubricant
e. g. Microlube GL 261
part no. 998 90 037 01
3
3
3
Flap to delivery unit
Torsion spring
2
2
2
Seal
2
2
2
Locking function
2
2
2
Chiller unit
Resources
Spare part number
Action/Frequency
1 = clean
2 = test/ check
3 = lubricate
4 = replace/ exchange
OK
12 Months or
30,000
1)
24 Months or
60,000
1)
36 Months or
90000
1)
Lint filter
(directly under the slide-out drawer)
Brush, air
1
1
1
Condenser
Brush, air
1
1
1
Compressor
Rinsing water
1
1
1
Evaporation tray
Rinsing water
1
1
1
Connecting gaskets, front, rear + left,
on the right side of the housing
Vaseline, rubber treatment
1 +2 +3
1 +2 +3
1 +2 +3
Glass door
Resources
Spare part number
Action/Frequency
1 = clean
2 = test/ check
3 = lubricate
4 = replace/ exchange
OK
12 Months or
30,000
1)
24 Months or
60,000
1)
36 Months or
90000
1)
Insulating glass panel
Rinsing water
1+2
1+2
1+2
Door seal
Vaseline, rubber treatment
2+3
2+3
2+3
Locking coach bolts
Special lubricant
e. g. Microlube GL 261
part no. 998 90 037 01
2+3
2+3
2+3
Lock
according to
manufacturer’s
specifications
2+3
2+3
2+3
9 Appendix: Maintenance schedule
ATTENTION! Risk of injury!
Maintenance work may be carried out only by a service engineer or specially trained personnel.
This maintenance schedule is purely to inform the machine operator about maintenance work and intervals (refer to
Technical manual).