36
4. Taking Measurements
4.8 Temperature Measurement “TEMP”
With the included temperature probe temperatures between -50 and
+204°C can be measured. With optionally available probes tempera-
tures of up to 1000°C can be measured.
Measuring Procedure
1. Connect the red measurement cable to the V/
Ω
/F/°C/
-Input (9)
and the black measurement cable to the COM-Input (8).
2. Set the rotary switch (4) to “TEMP”.
3. Now the temperature in °C can be read from the display. The
resolution is 1°C.
Notice:
Always use “K-type” temperature probes for precise results.