SAFETY & PRECAUTION
Electrical Service:
110V: A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power to the
pedicure spa. (220V if ordered in 220V configuration)
Water Supply:
All plumbing connections must conform to local codes. Normal water pressure of 30 to 80 PSI is required to correctly fill the
basin to the proper level. The hot water supply temperature must not exceed 150 F (65 C). Adjust your hot water heater
accordingly. Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the pedicure
spa. Shut-off valves are recommended.
Basin capacity:
4.5 US gallons of water per pedicure service.
Backflow Protection Devices for Faucets with Side Spray:
Check valves comply with ANSI/ASME A112.18.3M, A112.18.1M, and CSA B125 ANSI/ASME A112.18.3M (Performance
Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings) is applicable to plumbing fixture
fittings with outlets not protected by an air gap.
Included in the possible range of applications are fittings with hose connected outlets, fittings with pullout spout, hand held
showers, shampoo fittings and deck-mounted fittings. ASME A112.18.3M is now referenced in ASME A112.18.1M
(Plumbing Fixture Fittings) and CSA B125.
Check valves are listed to both standards with the Canadian Standards Association, IAPMO and UL. ANSI - American
National Standards Institute
ASME - American Society of Mechanical Engineers CSA - Canadian Standards Association IAPMO - International
Association of Plumbing and Mechanical Officials UL - Underwriters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided) must be installed by a
licensed plumber.
Important Installation and Utility Information
COMPLIANCE WITH LOCAL CODES OR
INSPECTIONS IS THE RESPONSIBILITY OF
THE PURCHASER AND/OR INSTALLER
2