background image

Unpacking

All Wharfedale Pro products are fully

checked before leaving the factory.

After unpacking please inspect

cabinets for any physical damage.

Please retain the shipping carton if

possible and internal packing material

in case the unit needs to be returned. Please check as soon

as possible the unit is functioning. In the event of any damage

please contact your dealer immediately so that a written claim

for damages can be made.

Wharfedale Pro Limited Warranty*

Wharfedale Pro EVP-XPSeries loudspeaker systems are warranted

to be clear of manufacturing or materials defects for a period of

one year from the original date of purchase. In the event of

malfunction, contact your authorised Wharfedale Professional

dealer or distributor for information.

*Be aware that warranty details may differ from country to

country. Contact your dealer or distributor for information.

These terms do not infringe your statutory rights.

W H A R F E D A L E   P R O   E V P - X P   S E R I E S

W A R N I N G   &   S A F E T Y I N S T R U C T I O N S

Wharfedale Pro EVP-XP Series of Professional Sound Reinforcement Loudspeakers

1. READ INSTRUCTIONS

carefully before operating this product.

2

.

RETAIN

these instructions.

3. COMPLY WITH WARNINGS - 

All warnings and instructions for

this product should be adhered to.

4.

WATER & MOISTURE 

This Wharfedale Pro unit should

not be used near liquids. If should not have liquids placed on or in
close proximity as there are 

DANGEROUS VOLTAGES

present. 

5. 

VENTILATION/AIR FLOW:  

This Wharfedale Pro unit

should not have its heat sinks obstructed from air flow. It should

not be situated in a built-in installation that may hamper air flow to

the heat sinks. It should not be placed near heat sources.

6. 

POWER SUPPLY:  

This Wharfedale Pro unit should be only

connected to a power supply as stated on the unit. Power supply

cables should be routed where they will not be walked on or

pinched by objects placed adjacent or upon them.

7. 

ELECTRIC SHOCK:  

Care should be taken that the grounding

of this unit is NOT defeated. Do not use this units power cable

with an extension cable unless the pins can be fully inserted.

7. CABLES - 

Use quality screened cables for signal connections.

8.

 

RIGGING • SUSPENDING • MOUNTING 

The rigging, suspension or mounting of this speaker system can

expose members of the public to serious health risks and even

death.  UNDER NO CIRCUMSTANCES ATTEMPT TO RIG,

SUSPEND OR OTHERWISE MOUNT THIS SYSTEM UNLESS

YOU ARE  FULLY QUALIFIED AND CERTIFIED TO DO SO BY

RELEVANT LOCAL, STATE AND NATIONAL AUTHORITIES.

ALL RELEVANT SAFETY REGULATIONS MUST BE

FOLLOWED.  IF YOU ARE NOT PROPERLY QUALIFIED OR DO

NOT KNOW OF PERTINENT REGULATIONS, CONSULT

QUALIFIED PERSONNEL FOR ADVICE AND ASSISTANCE. 

9.

CAUTION: 

These professional loudspeaker systems are

capable of generating very high sound pressure levels.  Use care

with placement and operation to avoid exposure to excessive

levels that can cause permanent hearing damage.

10. SERVICING - 

The user should not attempt to service this

product except that mentioned in this manual.

EVP-XP POWERED SERIES 
PROFESSIONAL LOUDSPEAKER 
USER MANUAL.

THIS USER MANUAL COVERS THE FOLLOWING MODELS:

EVP-X12P • EVP-X12PM • EVP-X15P • EVP-X15PM • 
EVP-X215P 
EVP-X15PB • EVP-X18PB Subwoofers

Page 1

Contents:

Page 1:  Warning and Safety Instructions

Page

 

2:  Specifications/Operating and Use

Page 3.  Product Features/ EVP-X1

2

PM

/15PM

 Panel

Page 4:  

EVP-X18PB Rear Panel Diagram

Page 5:  

EVP-X15PB and EVP-X18PB Operation

Page 6:  Single EVP-X18PB with Stereo Mid/High Active System and Stereo Active Sub and Mid/High System

Page 7:  Stereo Passive Mid/High Speaker with Active Sub System and EVP-X15P/18PB 

Block Diagram

Summary of Contents for EVP-X15P

Page 1: ...SUPPLY This Wharfedale Pro unit should be only connected to a power supply as stated on the unit Power supply cables should be routed where they will not be walked on or pinched by objects placed adjacent or upon them 7 ELECTRIC SHOCK Care should be taken that the grounding of this unit is NOT defeated Do not use this units power cable with an extension cable unless the pins can be fully inserted ...

Page 2: ...dB 10KHZ LF Shelving LF Shelving LF Shelving 12dB 80Hz 12dB 80HZ 12dB 80HZ ACTIVE CROSSOVER NA NA NA NA NA LPF 150HZ 24dB LPF 150Hz 24dB PHASE SWITCH NA NA NA NA NA 0 or 180º 0 or 180º POWER SECTION AMPLIFIER POWER CONTINUOUS 300W 300W 400W 400W 400W 400W 400W PEAK 500W 500W 600W 600W 600W 600W 600W EXTENSION SPEAKER OUTPUT NA 1 NA 1 NA NA NA PROTECTION TYPE Dynamic AGC Dynamic AGC Dynamic AGC Dyn...

Page 3: ...ipod stand adaptor except monitors Balanced line output Integral preset limiter prevents clipping distortion Combined Jack and XLR balanced input connectors Power on and system AGC protect LED indicators EVPX 15PB and EVPX 18PB Active Subwoofers Stereo line input and speaker level input available for the powered subwoofer Peak limiter that protects the amplifier and speaker from clipping 0 180 Pha...

Page 4: ...IA G L TD H UNTI NG TON UK 1 2 3 5 6 7 8 4 W H A R F E D A L E P R O E V P X P S E R I E S Page 4 ...

Page 5: ...ot affect OUTPUT A B 5 OUTPUT A B SWITCH This switch affects the s ignal se nt to the OUTPUT A B connectors THRU The INPUT A signal is passed directly to the OUTPUT A connector and INPUT B signal is passed directly to the OUTPUT B connector High Pass Filter HPF The INPUT A signal is first passed through a 100Hz 24dB High Pass Filter before being sent to the OUTPUT A connector whilst the INPUT B si...

Page 6: ...W H A R F E D A L E P R O E V P X P S E R I E S Page6 EVP X15P EVP X15P EVP X15P EVP X15P SINGLE EVP X18PB WITH STEREO MID HIGH ACTIVE SYSTEM STEREO ACTIVE SUB AND MID HIGH SYSTEM ...

Page 7: ...MIT 400W W H A R F E D A L E P R O E V P X P S E R I E S Page 7 POWER HIGH FREQUENCY LEVEL HIGH FREQUENCY LEVEL Boost Boost HIGH FREQUENCY LEVEL HIGH FREQUENCY LEVEL Boost Boost IAGLTD HUNTINGTON UK IAGLTD HUNTINGTON UK STEREO PASSIVE MID HIGH SPEAKER WITH ACTIVE SUB SYSTEM From Power Amplifier Left Output From Power Amplifier Right Output ...

Page 8: ...use Sovereign Court Ermine Business Park Huntingdon Cambs PE29 6XU England WHARFEDALE website www wharfedalepro com IAG Professional reserve the right to alter or improve specifications without notice All rights reserved 2004 Wharfedale Pro A member of the International Audio Group Page8 ...

Reviews: