4 - Time and Date Setting 

The 4000x series digital clocks can be configured to automa cally adjust for daylight savings changes, 

however if the unit is run in Standalone mode of opera on (i.e. unsynchronised), you may occasionally 

need to manually adjust the  me.Please refer to the diagram below for further informa on. 

Func on ‘Time Se ng Mode’.  Press ‘Up‘ to enter ‘Time Se ng Mode’ and set the seconds count. 

Seconds Se ng Mode.  Press ‘+’ to increment seconds, ‘-’ to set to zero.  Press ‘Up’ to set minutes count. 
Minutes Se ng Mode.  Press ‘+’ or ‘-’  to increment or decrement minutes.  Press ‘Up’ to set the hours 

count.  Complete  me se ng process detailed in table below. 
 

Fu Ti 

Time and Date  settings 

Function 

Display Type 

Description 

'Up' button function 

 

hh:mm (4200) 

hh:mm:ss 

(4010) 

 

 

Second 

36 

12 47  36 

Set second (minus bu on zeros seconds). 

Select minutes 

Minute 

12  47 

12  47  36 

Set minute. 

Select hours 

Hour 

12  47 

12  47 36 

Set hour. 

Select year 

Year 

20 14 

20 14 

Set year. 

Select month 

Month 

26  06 

26  06  14 

Set month. 

Select day of month 

Day of Month  26  06 

26  06 15 

Set day of month. 

Select Leap Second 

Leap Second 

LS  No 

LS  No 

Enable leap second - 59, No or 61. (Please leave at  

0 unless a leap second is scheduled) 

Exit to Time Display 

 
 

 

 

 

6

 Issue 2.2 

Summary of Contents for 4000x Series

Page 1: ...hronisa on Setup Page 9 7 Network Setup Page 12 8a Display Setup 4200x and 4010x series Page 13 8b Calendar Setup 4500x and 4600x series Page 14 9 Stopwatch Setup Page 15 10 External Interface Setup P...

Page 2: ...the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on The equ...

Page 3: ...sor All of the digital clocks also have the ability to operate as a mul range programmable stopwatch using supplied infrared remote control or for 4000NE and 4000E units only using an external stopwat...

Page 4: ...ould be easily accessible All installa on work should be performed in accordance with current Building Regula ons and the Seventeenth Edi on of the IEE Wiring Regula ons or equivalent local standard T...

Page 5: ...t se ng Func on Loca on Se ng Mode See page 5 1 Press Up to enter Loca on Se ng Mode or press to move to next se ng Func on Synchronisa on Se ng Mode See page 6 1 Press Up to enter Synchronisa on Se n...

Page 6: ...Up to set minutes count Minutes Se ng Mode Press or to increment or decrement minutes Press Up to set the hours count Complete me se ng process detailed in table below Fu Ti Time and Date settings Fu...

Page 7: ...ST MEZ MESZ Brussels Frankfurt 1 Yes 04 UTC 2 BRAVO SAST Jo burg Pretoria S Africa 2 No 05 EET EEST Greece Athens Ukraine Kiev 2 Yes 06 IST IDT Israel Tel Aviv 2 Yes 07 MSK 1 Russia Kaliningrad 3 No 0...

Page 8: ...n na Buenos Aires 3 No 63 BRT BRST Brazil Brasilia Sao Paulo 3 Yes 64 WGT WGST Greenland West Nuuk 3 Yes 65 PMST PMDT US Pierre Miquelon 3 Yes 66 UYT UYST Uruguay Montevideo 3 Yes 67 UTC 2 5 2 1 2 No...

Page 9: ...s DHCP server User se ng of NTP server addresses Exit to Time display dh No dh No Sta c assignment of IP Subnet and Gateway addresses by user User se ng of NTP server addresses Select IP Byte 1 IP Byt...

Page 10: ...2 Time code from exis ng 5200 4860 or 482D series master clock Y Y Y Zo 1 F w482 me code zone that unit will use for synchronisa on DCF DCF77 Radio me code synchronisa on requires 484 03 radio receive...

Page 11: ...d the Up arrow should be pressed again to return to the me display If clock is to DHCP or Sta c modes the 4 bytes of the rst NTP me server address can be programmed in same manner as detailed for the...

Page 12: ...to DCF or MSF radio me code when connected to either the 484 02 MSF Radio Receiver or 484 03 DCF Radio Receiver supplied separately as follows Clock configuration 1 Press Menu or Up bu on to access c...

Page 13: ...me date and con nuous date in a number of di erent display formats as detailed in the table below Fu Di Display Setup Function Display Type Description Up button function hh mm 4200 hh mm ss 4010 Disp...

Page 14: ...language table below Calendar 2 Mode Calendar 2 Mode M2 xx As mode se ngs for Calendar 1 above Calendar 2 Lang Calendar 2 Language C2 xx Calendar 2 Language as per language table below Calendar 3 Mod...

Page 15: ...ect hold mode SA 03 SA 03 Down from pre programmed start me then up from zero Select hold mode SA 04 SA 04 Down from pre programmed start me automa cally restart countdown Select hold mode Hold Mode S...

Page 16: ...n provide synchronisa on to a maximum 5 4000E units See Local Master documenta on for further details Exit to me display 11 System setup The system setup menu contains general setup op ons for the 400...

Reviews: