page 2 – 44
2001 / Jul 01
H A R D W A R E
DIPSW7 - Rack ID
If the OAN card is a Remote-Primary Audio Network Card, this OAN
card must supply the Rack ID to its backplane from the 4 bit onboard switch.
Remote Rack ID’s must be 5 or higher.
• Each remote chassis must have only one REMOTE-PRIMARY OAN
card.
Note: Rack ID numbers are coded in binary: Rack ID 1 equals binary Ø‚ Rack
ID 2 equals binary 1, etc.
Rack ID’s are set at the factory. Incorrect setting of these switches can cause
system malfunction.
Jumper Settings
J1 - Ethernet Mode Setting
Always shorted.
J2 - Reset
Momentary shorting does a complete reset.
RACK ID
1
SW7 RACK ID
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SW7
RACK ID8 RACK ID4 RACK ID2 RACK ID1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
MASTER CPU
RESERVED
FOR
STACKING
USED FOR
AUDIO
NETWORK
CHASSIS