A P P E N D I C E S
page A – 23
WheatNet-IP
/ Apr 2009
The left hand button on fader channel #1 will now function as an EQ In/Out switch.
In a like manner, other functions and other input channel buttons can be programmed.
To remove any programming from a button, choose CLEAR BUTTON PRO-
GRAMMING as the function, the button will now do nothing.
The programmable buttons on the main monitor panel have different functions tied
to more general control surface functions rather than input specific functions. Selecting
the Options>Programmable Buttons menu item on the main screen of the control
surface VGA display (this is password protected so you must have access privileges)
opens a drop down window listing the monitor panel programmable buttons (up to 14
max, the number will vary with the control surface model). For each button there is a
drop down window displaying its current operating mode. The default mode is
MOMENTARY/SURFACE LED.
The available programmed mode functions are:
Momentary/Surface LED: Causes the button function to be momentary and the
button LED indicator to be activated directly by the button’s position.
Tally LED: The button LED indicator becomes an available logic output to be
controlled externally.
Toggle: The button functions as an alternate action; push ON, push OFF switch.
Momentary/LIO LED: Causes the button function to be momentary and the
button LED indicator controlled externally.
Automation LIO: Causes the button to work with, and the LED indicator to be
controlled by, an external 3rd party device such as automation.