W H E A T N E T - I P S Y S T E M O P E R A T I O N A L M O D E S
page 2 – 10
WheatNet-IP
/ Apr 2009
Scroll the encoder to “1” and press the front panel switch; the front panel display will
show the default IP address of “192.168.87.101”. Once again, press the switch to accept the
IP address.
The display will show “I/O TEMPLATE: MONO_IO.” There are three signal templates
for WheatNet-IP 88a, 88ad, and 88d that the BLADE will use for automatically defining the
signals related to the input and output jacks. By turning the knob you can choose
“MONO_IO” to define all 16 inputs and outputs as mono signals, “STEREO_IO” to define
all inputs and outputs as eight stereo pairs, or “CUSTOM,” in which case no signals are
automatically defined. Choose “CUSTOM” only if you need a combination of mono and
stereo signals within the BLADE. You’ll have to do more work and define the signals
yourself.
For WheatNet-IP 88m there are two signal templates available. Choose from
“MONO_MIC” which creates eight microphone inputs and eight mono outputs, or
“STEREO_MIC” which creates eight microphone inputs and four stereo outputs.
WheatNet-IP
/ June 2010