page 2 – 28
FM-531HD / May 2013
F M - 5 3 1 H D G U R U G U I
With complex program material the FFT gives good visual feedback on the levels of audio
residing in different parts of the audio spectrum.
O-Scope
This is an oscilloscope‑type time‑domain display of the audio waveforms exiting the
output of the FM final peak control sections. The FM O‑scope display will reveal what the
pre‑emphasized and clipped audio looks like.
E vs. F
This display represents the RMS Loudness generated in each band of the FM or HD
path’s 31 limiter bands.
The E vs. F display has a submenu (shown left) that
allows customization of the RMS Integration Time, the
display Release Rate, and whether or not peak levels
are to be displayed. The factory default Integration
Time is 300mS – the same as a standard VU meter –
which is also a fair estimator for how loud something
seems to the human ear.
The submenu also allows you to adjust timings for the
SDR display (below).
Summary of Contents for FM-531 HD
Page 2: ...Technical Manual Wheatstone Corporation May 2013 FM HD Digital Audio Processor FM 531hd...
Page 122: ...page A 2 FM 531HD May 2013 A P P E N D I C E S Appendix A General Specifications A 3 Contents...