Quick Start - page 5
LXE / Feb 2018
Q U I C K S T A R T G U I D E
Power Supply
Front view of the PS-1600
rackmount power supply
Rear view of the PS-1600
rackmount power supply
If failsafe redundant sup-
plies have been ordered,
you will be installing two
PS-1600 units.
In case of redundancy use two PS-1600 units. If you are using one supply, connect
it to one of the control surface connectors (it doesn’t matter which one). If you are
using the failsafe option (two PS-1600 supplies), connect one end of a power supply
cable to either control surface power connector and connect the other end of the cable
to one of the two power supply units. Then use the other cable to connect the second
power supply to the remaining control surface power supply connector.
The LXE control surface is powered by a Wheatstone Model PS-1600
rackmount power supply. This unit occupies a single 19” wide rack space.
Convection cooled, it requires ample ventilation space above and below it.
Note the power supply (supplies) should be mounted in an equipment
rack within fifteen feet of the control surface (but no closer than 3 feet).
Avoid locating any high gain equipment too near the rackmount supplies,
to avoid magnetic interference into that equipment.
Once the supply is rackmounted, it should be connected
to the control surface using the factory supplied DC power
cable.
Unscrew the LXE’s rear panel to access its power
connectors that mounted on the bracket on the right side
of the chassis. The cable has two DC plugs on it.