Page 5
•
Activating the SIREN SHUTDOWN input will shut the
PIERCER tone down. However the HORN and the HORN
RING switch will activate an AIRHORN tone, and the MAN
switch will activate a momentary WAIL tone.
•
Activating the AUX ENABLE will have no effect.
MICROPHONE
Whenever the 295HFANC is powered on, activating the micro-
phone (pressing the switch on the side of the mic.) will shut down
any other siren functions and enable public address operation
regardless of the rotary switch position or any other switch or
input.
SPECIFICATIONS
INPUT VOLTAGE
. . . . . . . . . . . . . . . . . . . . .12.5 VDC ±20%
INPUT CURRENT
@15 VDC @ 5.5 OHMS.16 AMPS MAX.
INPUT FUSE
. . . . . . . . . . . . . . . . . . . . . . . . .20 AMPS
SPEAKER IMPEDANCE
. . . . . . . . . . . . . . .5.5 OHMS MIN.
OPERATING TEMPERATURE
. . . . . . . . . . .-30° C. TO +60° C.
STORAGE TEMPERATURE
. . . . . . . . . . . .-40° C. TO +70° C.
HUMIDITY
. . . . . . . . . . . . . . . . . . . . . . . . . . .99% (NON CONDENSING)
STROBE ICON OUTPUT
. . . . . . . . . . . . . . .12.5VDC ±20%@50mA (MAX)
DIAGNOSTIC INDICATORS
The 295HFANC has two diagnostic indicators on the front panel
which are used to indicate fault conditions with your siren system.
The following table lists the type of fault and the indicators
response. If the indicator is on steady while a tone is in use, this
means there is no fault with the associated speaker output.
Fault Condition
Diagnostic Indicators Response
Under Voltage
Speaker L.E.D. #2 will be in a double flash
mode (2 quick flashes followed by a longer
pause) and the siren tones will not operate.
Over Voltage
Speaker L.E.D. #1 will be in a double flash
mode (2 quick flashes followed by a longer
pause) and the siren tones will not operate
.
Speaker #1
Speaker L.E.D. # 1 will be in a single flash
Short Circuit
mode (the L.E.D. will be on and
off an equal amount of time) and the siren
tones will not operate.
Speaker #2
Speaker L.E.D. #2 will be in a single flash
Short Circuit
mode (the L.E.D. will be on and
off an equal
amount of time) and the siren
tones will not operate.
Speaker #1
Speaker L.E.D. #1 will be off (having a single
Open Circuit
speaker system will always
cause this condition for the speaker output
not in use) all tones will continue to operate.
Speaker #2
Speaker L.E.D. #2 will be off (having a single
Open Circuit
speaker system will always
cause this
condition for the speaker output
not in use) all tones will continue to operate.
POWER
RAD
MIC
PIER
YELP
WAIL
HF
MAN
PA
RAD
HORN
ON
SI TEST
1
2
PIN #
COLOR & GAGE
FUNCTION
1
RED 14GA
BLACK 14GA
2
BLUE 18GA
3
RED 14GA
4
BLACK 14GA
5
BLUE 18GA
6
BROWN 16GA
7
ORANGE 16GA
8
VIOLET 18GA
9
GRAY 18GA
10
WHITE 18GA
11
YELLOW 16GA
12
+ BATTERY
GROUND
RADIO
+ BATTERY
GROUND
RADIO
SPEAKER COM
+SPEAKER #2
AUX. ENABLE
HORN
HORN/RING
+SPEAKER #1
INPUT CONNECTOR ASSEMBLY
PIN 1
GREEN
SIREN ICON
FUNCTION
PIN #
COLOR
P1 1 P0S CONNECTOR
P1