Page 5

Activating the SIREN SHUTDOWN input will shut the 
PIERCER tone down. However the HORN and the HORN 
RING switch will activate an AIRHORN tone, and the MAN 
switch will activate a momentary WAIL tone.

Activating the AUX ENABLE will have no effect.

MICROPHONE

Whenever the 295HFANC is powered on, activating the micro-
phone (pressing the switch on the side of the mic.) will shut down 
any other siren functions and enable public address operation 
regardless of the rotary switch position or any other switch or 
input.

SPECIFICATIONS

INPUT VOLTAGE

. . . . . . . . . . . . . . . . . . . . .12.5 VDC ±20%

INPUT CURRENT 

@15 VDC @ 5.5 OHMS.16 AMPS MAX.

INPUT FUSE

. . . . . . . . . . . . . . . . . . . . . . . . .20 AMPS

SPEAKER IMPEDANCE

 . . . . . . . . . . . . . . .5.5 OHMS MIN.

OPERATING TEMPERATURE

. . . . . . . . . . .-30° C. TO +60° C.

STORAGE TEMPERATURE

 . . . . . . . . . . . .-40° C. TO +70° C.

HUMIDITY

. . . . . . . . . . . . . . . . . . . . . . . . . . .99% (NON CONDENSING)

STROBE ICON OUTPUT

. . . . . . . . . . . . . . .12.5VDC ±20%@50mA (MAX)

DIAGNOSTIC INDICATORS

The 295HFANC has two diagnostic indicators on the front panel 
which are used to indicate fault conditions with your siren system. 
The following table lists the type of fault and the indicators 
response. If the indicator is on steady while a tone is in use, this 
means there is no fault with the associated speaker output. 

Fault Condition

Diagnostic Indicators Response

Under Voltage

Speaker L.E.D. #2 will be in a double flash
mode (2 quick flashes followed by a longer
pause) and the siren tones will not operate.

Over Voltage

Speaker L.E.D. #1 will be in a double flash
mode (2 quick flashes followed by a longer
pause) and the siren tones will not operate

.

Speaker #1

Speaker L.E.D. # 1 will be in a single flash

Short Circuit

 mode (the L.E.D. will be on and

off an equal amount of time) and the siren
tones will not operate.

Speaker #2

Speaker L.E.D. #2 will be in a single flash

Short Circuit 

mode (the L.E.D. will be on and

off an equal

 

amount of time) and the siren

tones will not operate.

Speaker #1

Speaker L.E.D. #1 will be off (having a single

Open  Circuit 

speaker system will always

cause this condition for the speaker output
not in use) all tones will continue to operate.

Speaker #2

Speaker L.E.D. #2 will be off (having a single

Open  Circuit 

speaker system will always

cause this

 

condition for the speaker output

not in use) all tones will continue to operate.

POWER

RAD

MIC

PIER

YELP

WAIL

HF

MAN

PA

RAD

HORN

ON

SI TEST

1

2

PIN #

COLOR & GAGE

FUNCTION

1

RED 14GA

BLACK 14GA

2

BLUE 18GA

3

RED 14GA

4

BLACK 14GA

5

BLUE 18GA

6

BROWN 16GA

7

ORANGE 16GA

8

VIOLET 18GA

9

GRAY 18GA

10

WHITE 18GA

11

YELLOW 16GA

12

+ BATTERY

GROUND

RADIO

+ BATTERY

GROUND

RADIO

SPEAKER COM
+SPEAKER #2

AUX. ENABLE

HORN

HORN/RING

+SPEAKER #1

INPUT CONNECTOR ASSEMBLY

PIN 1

GREEN

SIREN ICON

FUNCTION

PIN #

COLOR

P1 1 P0S CONNECTOR

P1

Summary of Contents for 295HFANC

Page 1: ... be placed within convenient reach of the operator so that they can operate the system without taking their eyes off the roadway Emergency warning devices can require high electrical voltages and or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle...

Page 2: ...between the fuse block and the battery As the wire between the fuse and the battery is unprotected do not allow this wire to come in contact with any other wires 7 Connect the BLACK wire to the factory chassis ground adjacent to the battery Connecting Speaker Wires Yellow Orange Brown 1 Route the YELLOW ORANGE and BROWN wires along the factory wire harness and through the firewall at the same poin...

Page 3: ...ease the MAN button As the siren is tested its diagnostic indicator will turn on steady for about 1 5 seconds if no problems are detected If the indicator flashes or does not light at all a problem with either the siren speakers or wiring has been detected Check the wire connections of the failed speaker and repeat the SI TEST If the speaker fails to test again have the siren itself inspected by a...

Page 4: ...se and fall tone A third tap produces a piercer tone an extremely fast rise and fall tone The next tap returns the siren to a wail tone and the cycle repeats itself Two quick successive taps will stop the siren With the Rotary Switch in this Position Pressing the MAN switch will result in the HF cycle as described above Pressing the HORN switch will produce the AIRHORN tone until the HORN switch i...

Page 5: ...aker L E D 2 will be in a double flash mode 2 quick flashes followed by a longer pause and the siren tones will not operate Over Voltage Speaker L E D 1 will be in a double flash mode 2 quick flashes followed by a longer pause and the siren tones will not operate Speaker 1 Speaker L E D 1 will be in a single flash Short Circuit mode the L E D will be on and off an equal amount of time and the sire...